{"title":"模糊逻辑控制在双馈感应发电机外部故障无功和直流电容电压控制中的应用","authors":"Vibhuti Dhyani, Sudha Arora","doi":"10.1109/INDCON.2013.6725911","DOIUrl":null,"url":null,"abstract":"This paper presents application of fuzzy logic control for Reactive Power and D.C capacitor voltage control of Doubly Fed Induction Generator (DFIG) during external faults. In order to apply fuzzy logic controller, a model is developed in MATLAB/SIMULINK. Reactive power is control from rotor side converter and d.c. capacitor voltage is control from grid side converter. The simulation results are presented to illuminate the effectiveness of the fuzzy controller compared with conventional PI controller in the DFIG system.","PeriodicalId":313185,"journal":{"name":"2013 Annual IEEE India Conference (INDICON)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of fuzzy logic control for reactive power and D.C. capacitor voltage control of Doubly Fed Induction Generator during external faults\",\"authors\":\"Vibhuti Dhyani, Sudha Arora\",\"doi\":\"10.1109/INDCON.2013.6725911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents application of fuzzy logic control for Reactive Power and D.C capacitor voltage control of Doubly Fed Induction Generator (DFIG) during external faults. In order to apply fuzzy logic controller, a model is developed in MATLAB/SIMULINK. Reactive power is control from rotor side converter and d.c. capacitor voltage is control from grid side converter. The simulation results are presented to illuminate the effectiveness of the fuzzy controller compared with conventional PI controller in the DFIG system.\",\"PeriodicalId\":313185,\"journal\":{\"name\":\"2013 Annual IEEE India Conference (INDICON)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Annual IEEE India Conference (INDICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INDCON.2013.6725911\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual IEEE India Conference (INDICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDCON.2013.6725911","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of fuzzy logic control for reactive power and D.C. capacitor voltage control of Doubly Fed Induction Generator during external faults
This paper presents application of fuzzy logic control for Reactive Power and D.C capacitor voltage control of Doubly Fed Induction Generator (DFIG) during external faults. In order to apply fuzzy logic controller, a model is developed in MATLAB/SIMULINK. Reactive power is control from rotor side converter and d.c. capacitor voltage is control from grid side converter. The simulation results are presented to illuminate the effectiveness of the fuzzy controller compared with conventional PI controller in the DFIG system.