P. J. Martínez-Lacañina, A. Marcolini, J. Ramos
{"title":"DCOPF contingency analysis including phase shifting transformers","authors":"P. J. Martínez-Lacañina, A. Marcolini, J. Ramos","doi":"10.1109/PSCC.2014.7038442","DOIUrl":null,"url":null,"abstract":"This work deals with a new formulation for the Direct Current Optimal Power Flow (DCOPF) including the corrective actions related to the phase shifting transformers. The formulation is based on the outage of generators and/or branches modelled as fictitious injections of active power. The inclusion of the sensitivities of the phase shifting transformer with respect to the injected powers is one of the novelties of this paper. By including the fictitious injections in the optimization problem, the injections are adjusted to the post-contingency state as a consequence of the corrective actions carried out by the DCOPF to bring the system back to its normal state. Consequently, when the analysis of contingencies is performed, the classical topological analysis and the subsequent analyses are avoided with this approach. The DCOPF includes as corrective control variables the rescheduling of active power generations, phase shifting transformers and, if required, permitted load shedding. The IEEE-RTS of 24 buses is used as benchmark network to assess the properties of the proposed approach.","PeriodicalId":155801,"journal":{"name":"2014 Power Systems Computation Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Power Systems Computation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSCC.2014.7038442","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文讨论了直流最优潮流(DCOPF)的新公式,包括与移相变压器相关的纠正措施。该公式基于发电机和/或分支的停电,模拟为虚构的有功功率注入。将移相变压器的灵敏度与注入功率的关系考虑在内是本文的新颖之处之一。通过在优化问题中包含虚构的注入,注入被调整到事件后的状态,作为DCOPF执行的纠正行动的结果,使系统恢复到正常状态。因此,在进行偶然性分析时,该方法避免了传统的拓扑分析和后续分析。DCOPF包括作为校正控制变量的有功发电的重新调度,移相变压器,如果需要,允许减载。采用24总线的IEEE-RTS作为基准网络来评估所提出方法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DCOPF contingency analysis including phase shifting transformers
This work deals with a new formulation for the Direct Current Optimal Power Flow (DCOPF) including the corrective actions related to the phase shifting transformers. The formulation is based on the outage of generators and/or branches modelled as fictitious injections of active power. The inclusion of the sensitivities of the phase shifting transformer with respect to the injected powers is one of the novelties of this paper. By including the fictitious injections in the optimization problem, the injections are adjusted to the post-contingency state as a consequence of the corrective actions carried out by the DCOPF to bring the system back to its normal state. Consequently, when the analysis of contingencies is performed, the classical topological analysis and the subsequent analyses are avoided with this approach. The DCOPF includes as corrective control variables the rescheduling of active power generations, phase shifting transformers and, if required, permitted load shedding. The IEEE-RTS of 24 buses is used as benchmark network to assess the properties of the proposed approach.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信