交流电磁致微粒聚集位置的测定

Hukun Yang, Hongyuan Jiang, Hui Yan, C. Ma
{"title":"交流电磁致微粒聚集位置的测定","authors":"Hukun Yang, Hongyuan Jiang, Hui Yan, C. Ma","doi":"10.1109/ICIEA.2007.4318409","DOIUrl":null,"url":null,"abstract":"AC electroosmosis (AC EO) shows many advantages in collecting microparticles, such as low signal voltage, little sample, real-time detection and integrating in microchip easily. An experiment showed that the microparticles in sample would be accumulated on a fixed field on the surface of the microelectrodes caused by the AC electric field. Based on the phenomena, the velocity field of AC EO in microchannel is explored and the process of microparticles accumulated is explained. The location of microparticles accumulated is determined based on the numerical simulation results, at the same time, the rate relation between the accumulated location and the width of microelectrode, which offers the theoretic base for further analyzing and detecting microparticles.","PeriodicalId":231682,"journal":{"name":"2007 2nd IEEE Conference on Industrial Electronics and Applications","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of the Accumulated Location of Microparticle Collection Caused by AC EO\",\"authors\":\"Hukun Yang, Hongyuan Jiang, Hui Yan, C. Ma\",\"doi\":\"10.1109/ICIEA.2007.4318409\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"AC electroosmosis (AC EO) shows many advantages in collecting microparticles, such as low signal voltage, little sample, real-time detection and integrating in microchip easily. An experiment showed that the microparticles in sample would be accumulated on a fixed field on the surface of the microelectrodes caused by the AC electric field. Based on the phenomena, the velocity field of AC EO in microchannel is explored and the process of microparticles accumulated is explained. The location of microparticles accumulated is determined based on the numerical simulation results, at the same time, the rate relation between the accumulated location and the width of microelectrode, which offers the theoretic base for further analyzing and detecting microparticles.\",\"PeriodicalId\":231682,\"journal\":{\"name\":\"2007 2nd IEEE Conference on Industrial Electronics and Applications\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 2nd IEEE Conference on Industrial Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2007.4318409\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 2nd IEEE Conference on Industrial Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2007.4318409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

交流电渗透(AC EO)具有信号电压低、样品量小、检测实时、易于集成等优点。实验表明,在交流电场作用下,样品中的微粒会聚集在微电极表面的固定场上。在此基础上,探讨了微通道中交流电磁的速度场,并解释了微通道中微粒子的积累过程。根据数值模拟结果确定了微粒子积聚的位置,同时得到了微电极积聚位置与微电极宽度之间的速率关系,为进一步分析和检测微粒子提供了理论依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of the Accumulated Location of Microparticle Collection Caused by AC EO
AC electroosmosis (AC EO) shows many advantages in collecting microparticles, such as low signal voltage, little sample, real-time detection and integrating in microchip easily. An experiment showed that the microparticles in sample would be accumulated on a fixed field on the surface of the microelectrodes caused by the AC electric field. Based on the phenomena, the velocity field of AC EO in microchannel is explored and the process of microparticles accumulated is explained. The location of microparticles accumulated is determined based on the numerical simulation results, at the same time, the rate relation between the accumulated location and the width of microelectrode, which offers the theoretic base for further analyzing and detecting microparticles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信