热液PZT薄膜微超声手术刀

Y. Umehara, M. Kurosawa
{"title":"热液PZT薄膜微超声手术刀","authors":"Y. Umehara, M. Kurosawa","doi":"10.1109/ISAF.2006.4387901","DOIUrl":null,"url":null,"abstract":"A transducer for a micro ultrasonic scalpel has been fabricated. The micro ultrasonic scalpel can be used with an endoscope for a non-abdominal operation or micro surgery, for example, through a microscope. The ultrasonic transducer was 9.8 mm long and 2.7 mm wide and has stepped horn to amplify vibration velocity; tip of the horn is 0.6 mm wide. The scalpel vibrated in longitudinal mode at about 278 kHz resonance frequency. The piezoelectric material was lead zirconate titanate (PZT) that was deposited by the hydrothermal method. This is because the hydrothermal deposition film transducer has superior performance in vibration velocity. The vibration velocity at the tip of the horn in longitudinal direction was 4.0 m/s with 40 Vp-p driving voltage in both side electrodes. To demonstrate a beneficial effect of the scalpel, a cutting test that the transducer was stuck into pork fat was carried out. Efficient cutting performance was demonstrated using the transducer sized for an endoscope.","PeriodicalId":441219,"journal":{"name":"2006 15th ieee international symposium on the applications of ferroelectrics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Micro Ultrasonic Scalpel Using Hydrothermal PZT Thin Film\",\"authors\":\"Y. Umehara, M. Kurosawa\",\"doi\":\"10.1109/ISAF.2006.4387901\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A transducer for a micro ultrasonic scalpel has been fabricated. The micro ultrasonic scalpel can be used with an endoscope for a non-abdominal operation or micro surgery, for example, through a microscope. The ultrasonic transducer was 9.8 mm long and 2.7 mm wide and has stepped horn to amplify vibration velocity; tip of the horn is 0.6 mm wide. The scalpel vibrated in longitudinal mode at about 278 kHz resonance frequency. The piezoelectric material was lead zirconate titanate (PZT) that was deposited by the hydrothermal method. This is because the hydrothermal deposition film transducer has superior performance in vibration velocity. The vibration velocity at the tip of the horn in longitudinal direction was 4.0 m/s with 40 Vp-p driving voltage in both side electrodes. To demonstrate a beneficial effect of the scalpel, a cutting test that the transducer was stuck into pork fat was carried out. Efficient cutting performance was demonstrated using the transducer sized for an endoscope.\",\"PeriodicalId\":441219,\"journal\":{\"name\":\"2006 15th ieee international symposium on the applications of ferroelectrics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 15th ieee international symposium on the applications of ferroelectrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAF.2006.4387901\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 15th ieee international symposium on the applications of ferroelectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAF.2006.4387901","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

研制了一种微型超声手术刀的换能器。微型超声手术刀可以与内窥镜一起用于非腹部手术或显微手术,例如,通过显微镜。超声波换能器长9.8 mm,宽2.7 mm,阶梯式喇叭放大振动速度;喇叭的尖端是0.6毫米宽。手术刀以278千赫左右的共振频率纵向振动。压电材料为锆钛酸铅(PZT),采用水热法制备。这是因为热液沉积薄膜换能器在振动速度上具有优越的性能。喇叭尖端纵向振动速度为4.0 m/s,两侧电极驱动电压为40 Vp-p。为了证明手术刀的有益效果,进行了将换能器插入猪油中的切割试验。使用内窥镜尺寸的换能器证明了有效的切割性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Micro Ultrasonic Scalpel Using Hydrothermal PZT Thin Film
A transducer for a micro ultrasonic scalpel has been fabricated. The micro ultrasonic scalpel can be used with an endoscope for a non-abdominal operation or micro surgery, for example, through a microscope. The ultrasonic transducer was 9.8 mm long and 2.7 mm wide and has stepped horn to amplify vibration velocity; tip of the horn is 0.6 mm wide. The scalpel vibrated in longitudinal mode at about 278 kHz resonance frequency. The piezoelectric material was lead zirconate titanate (PZT) that was deposited by the hydrothermal method. This is because the hydrothermal deposition film transducer has superior performance in vibration velocity. The vibration velocity at the tip of the horn in longitudinal direction was 4.0 m/s with 40 Vp-p driving voltage in both side electrodes. To demonstrate a beneficial effect of the scalpel, a cutting test that the transducer was stuck into pork fat was carried out. Efficient cutting performance was demonstrated using the transducer sized for an endoscope.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信