微波时变负载的非线性测量

Chia-lun J. Hu
{"title":"微波时变负载的非线性测量","authors":"Chia-lun J. Hu","doi":"10.1109/ARFTG.1988.323924","DOIUrl":null,"url":null,"abstract":"When a high power microwave load is changing in time due to either microwave heating effect, or an environmental weathering effect, or a manual tuning of the load at high power level, or a manual sweeping of microwave power, the changing complex impedance (both magnitude and phase) is generally very difficult to monitored in real time. This paper reports an experimental result of the real-time nonlinear measurements of a standard time varying load operated at medium high power levels. The technique used is a well developed three-probe automatic impedance tracking measurement system. The real time nonlinear measurement capacity of the system is seen to be excellent. The error of measurements when the power level is changed while the load is kept constant is estimated to be within a few percents.","PeriodicalId":235867,"journal":{"name":"32nd ARFTG Conference Digest","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nonlinear Measurements of a Microwave Time-Varying Load\",\"authors\":\"Chia-lun J. Hu\",\"doi\":\"10.1109/ARFTG.1988.323924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When a high power microwave load is changing in time due to either microwave heating effect, or an environmental weathering effect, or a manual tuning of the load at high power level, or a manual sweeping of microwave power, the changing complex impedance (both magnitude and phase) is generally very difficult to monitored in real time. This paper reports an experimental result of the real-time nonlinear measurements of a standard time varying load operated at medium high power levels. The technique used is a well developed three-probe automatic impedance tracking measurement system. The real time nonlinear measurement capacity of the system is seen to be excellent. The error of measurements when the power level is changed while the load is kept constant is estimated to be within a few percents.\",\"PeriodicalId\":235867,\"journal\":{\"name\":\"32nd ARFTG Conference Digest\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"32nd ARFTG Conference Digest\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTG.1988.323924\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"32nd ARFTG Conference Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.1988.323924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

当高功率微波负载由于微波加热效应、环境风化效应、高功率负载的人工调谐或微波功率的人工扫频而发生时间变化时,其复杂阻抗(幅值和相位)的变化通常很难实时监测。本文报道了中大功率下标准时变负荷非线性实时测量的实验结果。所采用的技术是一种成熟的三探头阻抗自动跟踪测量系统。该系统具有良好的实时非线性测量能力。在负荷保持不变的情况下,当功率电平发生变化时,测量误差估计在几个百分点以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Nonlinear Measurements of a Microwave Time-Varying Load
When a high power microwave load is changing in time due to either microwave heating effect, or an environmental weathering effect, or a manual tuning of the load at high power level, or a manual sweeping of microwave power, the changing complex impedance (both magnitude and phase) is generally very difficult to monitored in real time. This paper reports an experimental result of the real-time nonlinear measurements of a standard time varying load operated at medium high power levels. The technique used is a well developed three-probe automatic impedance tracking measurement system. The real time nonlinear measurement capacity of the system is seen to be excellent. The error of measurements when the power level is changed while the load is kept constant is estimated to be within a few percents.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信