{"title":"亚毫米方针孔成像特性的初步研究","authors":"D. Xia, Mi-Ae Park, S. Moore, S. Metzler","doi":"10.1109/NSSMIC.2013.6829173","DOIUrl":null,"url":null,"abstract":"Recently, a square-pinhole collimator has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the fields of view (FOVs) in transverse and axial directions become separable. In this work, we have conducted sensitivity and FOV experiments for eighteen fabricated platinum/iridium(Pt/Ir) inserts with sub-millimeter square-apertures. A sinqθ fit to the experimental sensitivity has been performed for these inserts. The mean (standard deviation) of fitted sensitivity exponents (q) and effective diameters (d) are 10.7 (1.3) and 0.35 mm (0.02 mm), which are close to the values obtained from the simulated sensitivity data generated using the geometric parameters of the designed inserts. From projections of the FOV on the detector, we have measured the acceptance angles in the transverse and axial directions. The measured mean (standard deviation) of transverse and axial half-acceptances are 17.33° (0.21°) and 15.03°(0.23°), which are in good agreement with the designed values (17.13° and 14.93°). These results show that the physical properties of the fabricated inserts with sub-millimeter aperture size match our design well.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Preliminary investigation of imaging properties for sub-millimeter square pinholes\",\"authors\":\"D. Xia, Mi-Ae Park, S. Moore, S. Metzler\",\"doi\":\"10.1109/NSSMIC.2013.6829173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, a square-pinhole collimator has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the fields of view (FOVs) in transverse and axial directions become separable. In this work, we have conducted sensitivity and FOV experiments for eighteen fabricated platinum/iridium(Pt/Ir) inserts with sub-millimeter square-apertures. A sinqθ fit to the experimental sensitivity has been performed for these inserts. The mean (standard deviation) of fitted sensitivity exponents (q) and effective diameters (d) are 10.7 (1.3) and 0.35 mm (0.02 mm), which are close to the values obtained from the simulated sensitivity data generated using the geometric parameters of the designed inserts. From projections of the FOV on the detector, we have measured the acceptance angles in the transverse and axial directions. The measured mean (standard deviation) of transverse and axial half-acceptances are 17.33° (0.21°) and 15.03°(0.23°), which are in good agreement with the designed values (17.13° and 14.93°). These results show that the physical properties of the fabricated inserts with sub-millimeter aperture size match our design well.\",\"PeriodicalId\":246351,\"journal\":{\"name\":\"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2013.6829173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
近年来,人们提出了一种用于SPECT成像的方形针孔准直器,它可以有效地将投影平铺到探测器上,并且可以分离横向和轴向的视场。在这项工作中,我们对18个制造的亚毫米方形孔径铂/铱(Pt/Ir)插入物进行了灵敏度和视场实验。对这些插片进行了与实验灵敏度的sinqθ拟合。拟合的灵敏度指数(q)和有效直径(d)的均值(标准差)分别为10.7(1.3)和0.35 mm (0.02 mm),与利用设计刀片几何参数生成的模拟灵敏度数据得到的值接近。根据视场在探测器上的投影,我们测量了横向和轴向的接收角。实测的横向和轴向半接受度均值(标准差)分别为17.33°(0.21°)和15.03°(0.23°),与设计值(17.13°和14.93°)吻合较好。结果表明,制备的亚毫米孔径刀片的物理性能符合设计要求。
Preliminary investigation of imaging properties for sub-millimeter square pinholes
Recently, a square-pinhole collimator has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the fields of view (FOVs) in transverse and axial directions become separable. In this work, we have conducted sensitivity and FOV experiments for eighteen fabricated platinum/iridium(Pt/Ir) inserts with sub-millimeter square-apertures. A sinqθ fit to the experimental sensitivity has been performed for these inserts. The mean (standard deviation) of fitted sensitivity exponents (q) and effective diameters (d) are 10.7 (1.3) and 0.35 mm (0.02 mm), which are close to the values obtained from the simulated sensitivity data generated using the geometric parameters of the designed inserts. From projections of the FOV on the detector, we have measured the acceptance angles in the transverse and axial directions. The measured mean (standard deviation) of transverse and axial half-acceptances are 17.33° (0.21°) and 15.03°(0.23°), which are in good agreement with the designed values (17.13° and 14.93°). These results show that the physical properties of the fabricated inserts with sub-millimeter aperture size match our design well.