基于SDR和辐射传感器的局部放电信号检测与定位分析与比较

H. Mohamed, U. Khan, Mohsin Raza, Khaoula Abogila, M. Mohammed, Mohammed Alhaj
{"title":"基于SDR和辐射传感器的局部放电信号检测与定位分析与比较","authors":"H. Mohamed, U. Khan, Mohsin Raza, Khaoula Abogila, M. Mohammed, Mohammed Alhaj","doi":"10.1109/TELFOR52709.2021.9653331","DOIUrl":null,"url":null,"abstract":"Partial Discharge (PD) is an electrical discharge that occurs within part of the dielectric between two High Voltage (HV) conductors. PD causes damage to the dielectric which typically deteriorates with time. If left untreated, PD may result in catastrophic insulation failure, HV equipment destruction, and power supply disruption. PD detection plays a vital role in electrical power stations, it can help protect HV equipment. In this paper a comparison between two PD detection systems is presented. These systems are: PD detection system based on SDR technology, and PD detection system based on Radiometric sensors. Both systems can be deployed in a network to perform as a wireless sensor network. Results obtained using SDR technology are then compared to results obtained with the radiometric sensor.","PeriodicalId":330449,"journal":{"name":"2021 29th Telecommunications Forum (TELFOR)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Analysis and Comparison of Partial Discharge Signal Detection and Localization using SDR and radiometric sensor\",\"authors\":\"H. Mohamed, U. Khan, Mohsin Raza, Khaoula Abogila, M. Mohammed, Mohammed Alhaj\",\"doi\":\"10.1109/TELFOR52709.2021.9653331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial Discharge (PD) is an electrical discharge that occurs within part of the dielectric between two High Voltage (HV) conductors. PD causes damage to the dielectric which typically deteriorates with time. If left untreated, PD may result in catastrophic insulation failure, HV equipment destruction, and power supply disruption. PD detection plays a vital role in electrical power stations, it can help protect HV equipment. In this paper a comparison between two PD detection systems is presented. These systems are: PD detection system based on SDR technology, and PD detection system based on Radiometric sensors. Both systems can be deployed in a network to perform as a wireless sensor network. Results obtained using SDR technology are then compared to results obtained with the radiometric sensor.\",\"PeriodicalId\":330449,\"journal\":{\"name\":\"2021 29th Telecommunications Forum (TELFOR)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 29th Telecommunications Forum (TELFOR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TELFOR52709.2021.9653331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 29th Telecommunications Forum (TELFOR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TELFOR52709.2021.9653331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

局部放电(PD)是发生在两个高压(HV)导体之间的部分电介质内的放电。PD会对电介质造成损伤,而这种损伤通常会随着时间的推移而恶化。如果不及时处理,局部放电可能导致灾难性的绝缘失效、高压设备损坏和电源中断。局部放电检测在电站中起着至关重要的作用,它可以帮助保护高压设备。本文对两种局部放电检测系统进行了比较。这些系统分别是:基于SDR技术的PD检测系统和基于辐射传感器的PD检测系统。这两个系统都可以部署在一个网络中,作为一个无线传感器网络。然后将SDR技术得到的结果与辐射传感器得到的结果进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Analysis and Comparison of Partial Discharge Signal Detection and Localization using SDR and radiometric sensor
Partial Discharge (PD) is an electrical discharge that occurs within part of the dielectric between two High Voltage (HV) conductors. PD causes damage to the dielectric which typically deteriorates with time. If left untreated, PD may result in catastrophic insulation failure, HV equipment destruction, and power supply disruption. PD detection plays a vital role in electrical power stations, it can help protect HV equipment. In this paper a comparison between two PD detection systems is presented. These systems are: PD detection system based on SDR technology, and PD detection system based on Radiometric sensors. Both systems can be deployed in a network to perform as a wireless sensor network. Results obtained using SDR technology are then compared to results obtained with the radiometric sensor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信