基于粒子滤波的自动生成控制系统假数据注入攻击检测方法

Mohsen Khalaf, A. Youssef, E. El-Saadany
{"title":"基于粒子滤波的自动生成控制系统假数据注入攻击检测方法","authors":"Mohsen Khalaf, A. Youssef, E. El-Saadany","doi":"10.1109/EPEC.2018.8598446","DOIUrl":null,"url":null,"abstract":"Automatic Generation Control (AGC) systems adjust the power output of multiple generators at different power plants, in response to changes in the load. In addition to regulating the system frequency, AGC systems help to minimize the tie-line power deviation in multi-area systems. Given their reliance on communication links in order to send/receive mea-surements/control actions about frequency and power deviation in the power system, AGC systems are vulnerable to false data injection (FDI) attacks. Several works have considered the effect of these cyber attacks on AGC systems and many approaches have been proposed to detect FDI attacks against them. However, non of the previous works considered the nonlinearity of the AGC system and all the proposed solutions are only effective under the assumed linearity of the AGC model. In this work, we address this deficiency and propose a new particle filter-based approach to detect FDI attacks in AGC systems considering both the communication time-delay and governor dead-band nonlinearities. To confirm the effectiveness of this approach, a 2-area power system is simulated using MATLAB/Simulink. The results show that the utilized technique is capable of detecting various types of false data injection attacks against the considered AGC system.","PeriodicalId":265297,"journal":{"name":"2018 IEEE Electrical Power and Energy Conference (EPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A Particle Filter-Based Approach for the Detection of False Data Injection Attacks on Automatic Generation Control Systems\",\"authors\":\"Mohsen Khalaf, A. Youssef, E. El-Saadany\",\"doi\":\"10.1109/EPEC.2018.8598446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Automatic Generation Control (AGC) systems adjust the power output of multiple generators at different power plants, in response to changes in the load. In addition to regulating the system frequency, AGC systems help to minimize the tie-line power deviation in multi-area systems. Given their reliance on communication links in order to send/receive mea-surements/control actions about frequency and power deviation in the power system, AGC systems are vulnerable to false data injection (FDI) attacks. Several works have considered the effect of these cyber attacks on AGC systems and many approaches have been proposed to detect FDI attacks against them. However, non of the previous works considered the nonlinearity of the AGC system and all the proposed solutions are only effective under the assumed linearity of the AGC model. In this work, we address this deficiency and propose a new particle filter-based approach to detect FDI attacks in AGC systems considering both the communication time-delay and governor dead-band nonlinearities. To confirm the effectiveness of this approach, a 2-area power system is simulated using MATLAB/Simulink. The results show that the utilized technique is capable of detecting various types of false data injection attacks against the considered AGC system.\",\"PeriodicalId\":265297,\"journal\":{\"name\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2018.8598446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Power and Energy Conference (EPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2018.8598446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

自动发电控制(AGC)系统根据负荷的变化,调整不同电厂的多台发电机的输出功率。除了调节系统频率外,AGC系统还有助于减少多区域系统中的联络线功率偏差。由于AGC系统依赖通信链路来发送/接收有关电力系统中频率和功率偏差的测量/控制动作,因此AGC系统容易受到虚假数据注入(FDI)攻击。一些工作考虑了这些网络攻击对AGC系统的影响,并提出了许多方法来检测针对它们的FDI攻击。然而,以往的研究都没有考虑AGC系统的非线性,所提出的解都只在假定AGC模型为线性的情况下有效。在这项工作中,我们解决了这一不足,并提出了一种新的基于粒子滤波器的方法来检测AGC系统中的FDI攻击,同时考虑了通信时延和调节器死带非线性。为了验证该方法的有效性,利用MATLAB/Simulink对一个2区电力系统进行了仿真。结果表明,所采用的技术能够检测出针对所考虑的AGC系统的各种类型的虚假数据注入攻击。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Particle Filter-Based Approach for the Detection of False Data Injection Attacks on Automatic Generation Control Systems
Automatic Generation Control (AGC) systems adjust the power output of multiple generators at different power plants, in response to changes in the load. In addition to regulating the system frequency, AGC systems help to minimize the tie-line power deviation in multi-area systems. Given their reliance on communication links in order to send/receive mea-surements/control actions about frequency and power deviation in the power system, AGC systems are vulnerable to false data injection (FDI) attacks. Several works have considered the effect of these cyber attacks on AGC systems and many approaches have been proposed to detect FDI attacks against them. However, non of the previous works considered the nonlinearity of the AGC system and all the proposed solutions are only effective under the assumed linearity of the AGC model. In this work, we address this deficiency and propose a new particle filter-based approach to detect FDI attacks in AGC systems considering both the communication time-delay and governor dead-band nonlinearities. To confirm the effectiveness of this approach, a 2-area power system is simulated using MATLAB/Simulink. The results show that the utilized technique is capable of detecting various types of false data injection attacks against the considered AGC system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信