Min Wang, Yuan Chen, Zixuan Yu, Huilin Wang, Fanglin Zuo, Jian Zhou, S. Shi
{"title":"基于配电区域的空调负荷可调容量分析","authors":"Min Wang, Yuan Chen, Zixuan Yu, Huilin Wang, Fanglin Zuo, Jian Zhou, S. Shi","doi":"10.1109/AEEES54426.2022.9759403","DOIUrl":null,"url":null,"abstract":"As a typical flexible load, the air-conditioning load has a more significant potential for regulation due to its vast volume and the thermal inertia of the building to which it belongs. Due to the differences in the working principles and operating characteristics of air-conditioning loads in different buildings, the modeling methods and adjustment methods are also very different, including distributed air-conditioning and central air-conditioning systems. Therefore, this paper studies the equivalent thermal parameter models of air-conditioning loads under different control methods and analyzes the air-conditioning load regulation capacity of various types of buildings on a regional basis, then evaluates the adjustable amount of air-conditioning load in the power distribution area participating in the dispatch.","PeriodicalId":252797,"journal":{"name":"2022 4th Asia Energy and Electrical Engineering Symposium (AEEES)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Adjustable Capacity of Air Conditioning Load Based on the Power Distribution Area\",\"authors\":\"Min Wang, Yuan Chen, Zixuan Yu, Huilin Wang, Fanglin Zuo, Jian Zhou, S. Shi\",\"doi\":\"10.1109/AEEES54426.2022.9759403\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As a typical flexible load, the air-conditioning load has a more significant potential for regulation due to its vast volume and the thermal inertia of the building to which it belongs. Due to the differences in the working principles and operating characteristics of air-conditioning loads in different buildings, the modeling methods and adjustment methods are also very different, including distributed air-conditioning and central air-conditioning systems. Therefore, this paper studies the equivalent thermal parameter models of air-conditioning loads under different control methods and analyzes the air-conditioning load regulation capacity of various types of buildings on a regional basis, then evaluates the adjustable amount of air-conditioning load in the power distribution area participating in the dispatch.\",\"PeriodicalId\":252797,\"journal\":{\"name\":\"2022 4th Asia Energy and Electrical Engineering Symposium (AEEES)\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 4th Asia Energy and Electrical Engineering Symposium (AEEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEEES54426.2022.9759403\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 4th Asia Energy and Electrical Engineering Symposium (AEEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEEES54426.2022.9759403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of Adjustable Capacity of Air Conditioning Load Based on the Power Distribution Area
As a typical flexible load, the air-conditioning load has a more significant potential for regulation due to its vast volume and the thermal inertia of the building to which it belongs. Due to the differences in the working principles and operating characteristics of air-conditioning loads in different buildings, the modeling methods and adjustment methods are also very different, including distributed air-conditioning and central air-conditioning systems. Therefore, this paper studies the equivalent thermal parameter models of air-conditioning loads under different control methods and analyzes the air-conditioning load regulation capacity of various types of buildings on a regional basis, then evaluates the adjustable amount of air-conditioning load in the power distribution area participating in the dispatch.