康普顿前列腺探针的第一个原型的结果

C. Lacasta, J. Bernabeu, D. Burdette, E. Chesi, N. Clinthorne, Y. Dewaraja, K. Honscheid, H. Kagan, G. Llosá, M. Mikuž, P. Modesto, W. Rogers, A. Studen, P. Weilhammer, L. Zhang, D. Žontar
{"title":"康普顿前列腺探针的第一个原型的结果","authors":"C. Lacasta, J. Bernabeu, D. Burdette, E. Chesi, N. Clinthorne, Y. Dewaraja, K. Honscheid, H. Kagan, G. Llosá, M. Mikuž, P. Modesto, W. Rogers, A. Studen, P. Weilhammer, L. Zhang, D. Žontar","doi":"10.1109/NSSMIC.2005.1596208","DOIUrl":null,"url":null,"abstract":"A first prototype of a Compton prostate probe has been built using a stack of five 4times1 cm2, 1 mm thick silicon pad detectors as a scatter detector, surrounded by three scintillation detectors in which the absorption of the scattered photons takes place. The silicon pad dimensions are 1.4times1.4 mm which provide the required spatial resolution. The energy resolution in the silicon sensors is about 1.4 keV FWHM as determined from several gamma sources. The results obtained validate the simulation predictions that foresee an improvement over current SPECT techniques by a factor 16-40 in sensitivity and 4-5 in spatial resolution simultaneously for an intra-rectal probe built employing this concept and placed at 2 cm from the prostate","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"313 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Results from a first prototype of a Compton prostate probe\",\"authors\":\"C. Lacasta, J. Bernabeu, D. Burdette, E. Chesi, N. Clinthorne, Y. Dewaraja, K. Honscheid, H. Kagan, G. Llosá, M. Mikuž, P. Modesto, W. Rogers, A. Studen, P. Weilhammer, L. Zhang, D. Žontar\",\"doi\":\"10.1109/NSSMIC.2005.1596208\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A first prototype of a Compton prostate probe has been built using a stack of five 4times1 cm2, 1 mm thick silicon pad detectors as a scatter detector, surrounded by three scintillation detectors in which the absorption of the scattered photons takes place. The silicon pad dimensions are 1.4times1.4 mm which provide the required spatial resolution. The energy resolution in the silicon sensors is about 1.4 keV FWHM as determined from several gamma sources. The results obtained validate the simulation predictions that foresee an improvement over current SPECT techniques by a factor 16-40 in sensitivity and 4-5 in spatial resolution simultaneously for an intra-rectal probe built employing this concept and placed at 2 cm from the prostate\",\"PeriodicalId\":105619,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"volume\":\"313 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2005.1596208\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

康普顿前列腺探针的第一个原型已经建成,它使用了5个4倍1平方厘米,1毫米厚的硅衬垫探测器作为散射探测器,周围是3个闪烁探测器,其中吸收了散射光子。硅衬垫尺寸为1.4 × 1.4 mm,提供所需的空间分辨率。硅传感器的能量分辨率约为1.4 keV FWHM,由几个伽马源确定。所获得的结果验证了模拟预测,即对于采用该概念并放置在距前列腺2厘米处的直肠内探针,预测比当前SPECT技术在灵敏度上提高16-40倍,同时在空间分辨率上提高4-5倍
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Results from a first prototype of a Compton prostate probe
A first prototype of a Compton prostate probe has been built using a stack of five 4times1 cm2, 1 mm thick silicon pad detectors as a scatter detector, surrounded by three scintillation detectors in which the absorption of the scattered photons takes place. The silicon pad dimensions are 1.4times1.4 mm which provide the required spatial resolution. The energy resolution in the silicon sensors is about 1.4 keV FWHM as determined from several gamma sources. The results obtained validate the simulation predictions that foresee an improvement over current SPECT techniques by a factor 16-40 in sensitivity and 4-5 in spatial resolution simultaneously for an intra-rectal probe built employing this concept and placed at 2 cm from the prostate
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信