{"title":"并网太阳能光伏(SPV)系统逆变器替代控制策略","authors":"S. Bagchi, D. Chatterjee, R. Bhaduri, P. Biswas","doi":"10.1109/PIICON49524.2020.9113020","DOIUrl":null,"url":null,"abstract":"Use of distribution generation (DG) system in large scale is becoming an encouraging scenario for electric power generation. For this purpose, three-phase voltage source inverter (VSI) carried out a major role to link between DG and grid. The inverter must be operated smoothly and stay connected during voltage sag or any kind of disturbances takes place. Till date, several control strategies have been invented and also implemented in different systems globally to maintain the healthy operation of the inverter. This paper proposes an alternative method to control the voltage source inverter of grid-connected solar photovoltaic (SPV) system. The proposed work is focused on an alternative inverter control process based on a synchronously reference frame phase-locked loop (SRF-PLL). A modified dual-loop feedback control strategy has been introduced and implemented in the proposed system to show effective control of a three-phase grid-connected voltage source inverter. All the simulations have been carried out and verified in MATLAB/SIMULINK environment.","PeriodicalId":422853,"journal":{"name":"2020 IEEE 9th Power India International Conference (PIICON)","volume":"03 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"An Alternative Inverter Control Strategy for Grid Connected Solar Photovoltaic (SPV) System\",\"authors\":\"S. Bagchi, D. Chatterjee, R. Bhaduri, P. Biswas\",\"doi\":\"10.1109/PIICON49524.2020.9113020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Use of distribution generation (DG) system in large scale is becoming an encouraging scenario for electric power generation. For this purpose, three-phase voltage source inverter (VSI) carried out a major role to link between DG and grid. The inverter must be operated smoothly and stay connected during voltage sag or any kind of disturbances takes place. Till date, several control strategies have been invented and also implemented in different systems globally to maintain the healthy operation of the inverter. This paper proposes an alternative method to control the voltage source inverter of grid-connected solar photovoltaic (SPV) system. The proposed work is focused on an alternative inverter control process based on a synchronously reference frame phase-locked loop (SRF-PLL). A modified dual-loop feedback control strategy has been introduced and implemented in the proposed system to show effective control of a three-phase grid-connected voltage source inverter. All the simulations have been carried out and verified in MATLAB/SIMULINK environment.\",\"PeriodicalId\":422853,\"journal\":{\"name\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"volume\":\"03 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIICON49524.2020.9113020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 9th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIICON49524.2020.9113020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

分布式发电(DG)系统的大规模使用正成为一种令人鼓舞的发电方案。为此,三相电压源逆变器(VSI)在连接DG与电网之间发挥了重要作用。逆变器必须平稳运行,并在电压下降或任何干扰发生时保持连接。到目前为止,已经发明了几种控制策略,并在全球不同的系统中实施,以保持逆变器的健康运行。本文提出了一种控制并网太阳能光伏系统电压源逆变器的替代方法。提出的工作重点是基于同步参考帧锁相环(SRF-PLL)的替代逆变器控制过程。提出了一种改进的双环反馈控制策略,并在系统中实现了对三相并网电压源逆变器的有效控制。所有的仿真都在MATLAB/SIMULINK环境下进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Alternative Inverter Control Strategy for Grid Connected Solar Photovoltaic (SPV) System
Use of distribution generation (DG) system in large scale is becoming an encouraging scenario for electric power generation. For this purpose, three-phase voltage source inverter (VSI) carried out a major role to link between DG and grid. The inverter must be operated smoothly and stay connected during voltage sag or any kind of disturbances takes place. Till date, several control strategies have been invented and also implemented in different systems globally to maintain the healthy operation of the inverter. This paper proposes an alternative method to control the voltage source inverter of grid-connected solar photovoltaic (SPV) system. The proposed work is focused on an alternative inverter control process based on a synchronously reference frame phase-locked loop (SRF-PLL). A modified dual-loop feedback control strategy has been introduced and implemented in the proposed system to show effective control of a three-phase grid-connected voltage source inverter. All the simulations have been carried out and verified in MATLAB/SIMULINK environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信