一种无创确定脑顺应性的信号分析算法

P. Manwaring, D. Wichern, M. Manwaring, J. Manwaring, K. Manwaring
{"title":"一种无创确定脑顺应性的信号分析算法","authors":"P. Manwaring, D. Wichern, M. Manwaring, J. Manwaring, K. Manwaring","doi":"10.1109/ISSMD.2004.1689554","DOIUrl":null,"url":null,"abstract":"Patients with increased intracranial pressure (ICP) caused by hydrocephalus or brain injury have poor brain compliance or increased brain stiffness. The condition is commonly treated by a surgical diversion of cerebrospinal fluid (CSF) through placement of a ventriculoperitoneal (VP) shunt. These inserted devices frequently fail and require replacement. Assessment of failed devices typically requires an invasive surgical procedure to implant an ICP sensor. Brain compliance can be determined non-invasively by comparing the intracranial pressure (ICP) waveform to the digital artery waveform. The ICP waveform is derived from a piezo sensor snugged into the external ear canal and worn as a headset. The digital artery waveform is derived from a stand pulse oximeter. Digital signal processing performed on sampled data from these two sensors shows a time-lag or phase relationship between the two waves which widens with worsening brain stiffness or compliance. An algorithm is presented that shows how these signals can be used to compute brain compliance. An instrument designed to calculate real-time brain compliance to aid healthcare professionals is described.","PeriodicalId":193326,"journal":{"name":"The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A signal analysis algorithm for determining brain compliance non-invasively\",\"authors\":\"P. Manwaring, D. Wichern, M. Manwaring, J. Manwaring, K. Manwaring\",\"doi\":\"10.1109/ISSMD.2004.1689554\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Patients with increased intracranial pressure (ICP) caused by hydrocephalus or brain injury have poor brain compliance or increased brain stiffness. The condition is commonly treated by a surgical diversion of cerebrospinal fluid (CSF) through placement of a ventriculoperitoneal (VP) shunt. These inserted devices frequently fail and require replacement. Assessment of failed devices typically requires an invasive surgical procedure to implant an ICP sensor. Brain compliance can be determined non-invasively by comparing the intracranial pressure (ICP) waveform to the digital artery waveform. The ICP waveform is derived from a piezo sensor snugged into the external ear canal and worn as a headset. The digital artery waveform is derived from a stand pulse oximeter. Digital signal processing performed on sampled data from these two sensors shows a time-lag or phase relationship between the two waves which widens with worsening brain stiffness or compliance. An algorithm is presented that shows how these signals can be used to compute brain compliance. An instrument designed to calculate real-time brain compliance to aid healthcare professionals is described.\",\"PeriodicalId\":193326,\"journal\":{\"name\":\"The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISSMD.2004.1689554\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSMD.2004.1689554","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

脑积水或脑损伤引起的颅内压增高患者脑顺应性差或脑僵硬度增高。这种情况通常通过脑室-腹膜(VP)分流术转移脑脊液(CSF)。这些插入的设备经常发生故障,需要更换。对失效设备的评估通常需要侵入性的外科手术来植入ICP传感器。通过比较颅内压(ICP)波形和指动脉波形,可以无创地确定脑顺应性。ICP波形来自于外耳道内的压电传感器,并作为耳机佩戴。数字动脉波形来自于立式脉搏血氧计。对来自这两个传感器的采样数据进行的数字信号处理显示,两个波之间存在时滞或相位关系,随着大脑僵硬或顺应性的恶化而变宽。提出了一种算法,说明如何使用这些信号来计算大脑顺应性。描述了一种用于计算实时脑顺应性的仪器,以帮助医疗保健专业人员。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A signal analysis algorithm for determining brain compliance non-invasively
Patients with increased intracranial pressure (ICP) caused by hydrocephalus or brain injury have poor brain compliance or increased brain stiffness. The condition is commonly treated by a surgical diversion of cerebrospinal fluid (CSF) through placement of a ventriculoperitoneal (VP) shunt. These inserted devices frequently fail and require replacement. Assessment of failed devices typically requires an invasive surgical procedure to implant an ICP sensor. Brain compliance can be determined non-invasively by comparing the intracranial pressure (ICP) waveform to the digital artery waveform. The ICP waveform is derived from a piezo sensor snugged into the external ear canal and worn as a headset. The digital artery waveform is derived from a stand pulse oximeter. Digital signal processing performed on sampled data from these two sensors shows a time-lag or phase relationship between the two waves which widens with worsening brain stiffness or compliance. An algorithm is presented that shows how these signals can be used to compute brain compliance. An instrument designed to calculate real-time brain compliance to aid healthcare professionals is described.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信