{"title":"变压器少,THD低,逆变系统效率高","authors":"Md. Khurshedul Islam, Md. Mizanur Rahman, Md. Fazle Rabbi","doi":"10.1109/ICAEE.2015.7506853","DOIUrl":null,"url":null,"abstract":"Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system', a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system' efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system' than `general inverter system'.","PeriodicalId":123939,"journal":{"name":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Transformer less, lower THD and highly efficient inverter system\",\"authors\":\"Md. Khurshedul Islam, Md. Mizanur Rahman, Md. Fazle Rabbi\",\"doi\":\"10.1109/ICAEE.2015.7506853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system', a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system' efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system' than `general inverter system'.\",\"PeriodicalId\":123939,\"journal\":{\"name\":\"2015 International Conference on Advances in Electrical Engineering (ICAEE)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Advances in Electrical Engineering (ICAEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAEE.2015.7506853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE.2015.7506853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transformer less, lower THD and highly efficient inverter system
Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system', a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system' efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system' than `general inverter system'.