MEMS陀螺仪的比例因子:电源电压的影响

Martin Vagner, P. Benes
{"title":"MEMS陀螺仪的比例因子:电源电压的影响","authors":"Martin Vagner, P. Benes","doi":"10.1109/ICSENST.2013.6727652","DOIUrl":null,"url":null,"abstract":"This paper discusses the behavior of MEMS gyroscopes during power supply fluctuations, which is a problem that has not been sufficiently analyzed to date. The focus is placed on the scale factor. In the opening section, the authors present the basic output configurations of the MEMS gyroscopes and propose their general models. The following part of the article has a practical character. Here, eight types of the above-defined gyroscopes are examined to demonstrate the influence of the applied supply voltage. Firstly, the measurement procedure is described, and subsequently the results of this experiment are presented. The outcome of the performed research consists in that the scale factor error is smaller than 1% if the power supply voltage fluctuates within the range of ±0.25 V around the nominal value.","PeriodicalId":374655,"journal":{"name":"2013 Seventh International Conference on Sensing Technology (ICST)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Scale factor in MEMS gyroscopes: The effect of power supply voltage\",\"authors\":\"Martin Vagner, P. Benes\",\"doi\":\"10.1109/ICSENST.2013.6727652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the behavior of MEMS gyroscopes during power supply fluctuations, which is a problem that has not been sufficiently analyzed to date. The focus is placed on the scale factor. In the opening section, the authors present the basic output configurations of the MEMS gyroscopes and propose their general models. The following part of the article has a practical character. Here, eight types of the above-defined gyroscopes are examined to demonstrate the influence of the applied supply voltage. Firstly, the measurement procedure is described, and subsequently the results of this experiment are presented. The outcome of the performed research consists in that the scale factor error is smaller than 1% if the power supply voltage fluctuates within the range of ±0.25 V around the nominal value.\",\"PeriodicalId\":374655,\"journal\":{\"name\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2013.6727652\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Seventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2013.6727652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文讨论了MEMS陀螺仪在电源波动时的行为,这是一个迄今尚未得到充分分析的问题。重点放在比例因子上。在开头部分,作者介绍了MEMS陀螺仪的基本输出配置,并提出了它们的一般模型。文章的下一部分具有实践性。在这里,八种类型的上述陀螺仪进行了检查,以证明施加的电源电压的影响。首先介绍了测量过程,然后给出了实验结果。研究结果表明,当电源电压在标称值周围±0.25 V范围内波动时,比例因子误差小于1%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Scale factor in MEMS gyroscopes: The effect of power supply voltage
This paper discusses the behavior of MEMS gyroscopes during power supply fluctuations, which is a problem that has not been sufficiently analyzed to date. The focus is placed on the scale factor. In the opening section, the authors present the basic output configurations of the MEMS gyroscopes and propose their general models. The following part of the article has a practical character. Here, eight types of the above-defined gyroscopes are examined to demonstrate the influence of the applied supply voltage. Firstly, the measurement procedure is described, and subsequently the results of this experiment are presented. The outcome of the performed research consists in that the scale factor error is smaller than 1% if the power supply voltage fluctuates within the range of ±0.25 V around the nominal value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信