{"title":"3D打印的同轴传感器检测生物液体的介电光谱高达130GHz","authors":"Xiandong Liu, G. Su, Yuchao Lei, Nanjia Zhou, Zemin Su, Lingling Sun","doi":"10.1109/UCMMT45316.2018.9015663","DOIUrl":null,"url":null,"abstract":"This paper introduces a coaxial sensor with 3D printing technology to detect the dielectric spectrum of biological liquid samples from DC to 130 GHz. The biological liquids are filled in the space between the coaxial inner conductor and the outer conductor. Microfluidic channel is designed for the input and output of the liquid in the coaxial sensor. A special Short-Open-Load-Thru (SOLT) calibration kits are designed to facilitate the extraction of the dielectric spectrum. A simple de-embedding method based on ABCD matrices is adopted, by a multi-step method to extract the dielectric constant within the frequency.","PeriodicalId":326539,"journal":{"name":"2018 11th UK-Europe-China Workshop on Millimeter Waves and Terahertz Technologies (UCMMT)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A coaxial sensor with 3D printing detect the dielectric spectrum of biological liquid up to 130GHz\",\"authors\":\"Xiandong Liu, G. Su, Yuchao Lei, Nanjia Zhou, Zemin Su, Lingling Sun\",\"doi\":\"10.1109/UCMMT45316.2018.9015663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces a coaxial sensor with 3D printing technology to detect the dielectric spectrum of biological liquid samples from DC to 130 GHz. The biological liquids are filled in the space between the coaxial inner conductor and the outer conductor. Microfluidic channel is designed for the input and output of the liquid in the coaxial sensor. A special Short-Open-Load-Thru (SOLT) calibration kits are designed to facilitate the extraction of the dielectric spectrum. A simple de-embedding method based on ABCD matrices is adopted, by a multi-step method to extract the dielectric constant within the frequency.\",\"PeriodicalId\":326539,\"journal\":{\"name\":\"2018 11th UK-Europe-China Workshop on Millimeter Waves and Terahertz Technologies (UCMMT)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 11th UK-Europe-China Workshop on Millimeter Waves and Terahertz Technologies (UCMMT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UCMMT45316.2018.9015663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 11th UK-Europe-China Workshop on Millimeter Waves and Terahertz Technologies (UCMMT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UCMMT45316.2018.9015663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种采用3D打印技术的同轴传感器,用于检测生物液体样品在直流至130 GHz范围内的介电光谱。生物液体填充在同轴内导体和外导体之间的空间中。在同轴传感器中,为液体的输入和输出设计了微流控通道。设计了一种特殊的短开负载通过(SOLT)校准套件,以方便提取介电谱。采用一种简单的基于ABCD矩阵的去嵌入方法,通过多步提取频率内的介电常数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A coaxial sensor with 3D printing detect the dielectric spectrum of biological liquid up to 130GHz
This paper introduces a coaxial sensor with 3D printing technology to detect the dielectric spectrum of biological liquid samples from DC to 130 GHz. The biological liquids are filled in the space between the coaxial inner conductor and the outer conductor. Microfluidic channel is designed for the input and output of the liquid in the coaxial sensor. A special Short-Open-Load-Thru (SOLT) calibration kits are designed to facilitate the extraction of the dielectric spectrum. A simple de-embedding method based on ABCD matrices is adopted, by a multi-step method to extract the dielectric constant within the frequency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信