计算塔浪涌阻抗的仿真模型

Zhijin Zhang, W. Sima, Yongji Zhang, L. Shu
{"title":"计算塔浪涌阻抗的仿真模型","authors":"Zhijin Zhang, W. Sima, Yongji Zhang, L. Shu","doi":"10.1109/ELINSL.2004.1380581","DOIUrl":null,"url":null,"abstract":"Tower surge impedance is an important parameter in the prediction of HV and EHV lightning outage rates. Several attempts have been made to measure it experimentally on full scale towers, and formulas to calculate this parameter have been proposed by Jordan, Wanger and Sargent, etc. However, the values of surge impedance calculated using these relationships are in poor agreement with each other and, in general, with the various measured values. This paper presents a simulation model of uneven distributing parameter for determining the surge impedance of towers by the Electromagnetic Transients Program (EMTP). This paper also demonstrates that the values so obtained describe the response of the tower adequately when a transmission line is struck by lightning, Furthermore, the simulation value of tower surge impedance is close to the actual test value and the relative error is ten percent.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"94 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"The simulation model for calculating the surge impedance of a tower\",\"authors\":\"Zhijin Zhang, W. Sima, Yongji Zhang, L. Shu\",\"doi\":\"10.1109/ELINSL.2004.1380581\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tower surge impedance is an important parameter in the prediction of HV and EHV lightning outage rates. Several attempts have been made to measure it experimentally on full scale towers, and formulas to calculate this parameter have been proposed by Jordan, Wanger and Sargent, etc. However, the values of surge impedance calculated using these relationships are in poor agreement with each other and, in general, with the various measured values. This paper presents a simulation model of uneven distributing parameter for determining the surge impedance of towers by the Electromagnetic Transients Program (EMTP). This paper also demonstrates that the values so obtained describe the response of the tower adequately when a transmission line is struck by lightning, Furthermore, the simulation value of tower surge impedance is close to the actual test value and the relative error is ten percent.\",\"PeriodicalId\":342687,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"volume\":\"94 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2004.1380581\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380581","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

塔架浪涌阻抗是预测高压、特高压雷击中断率的重要参数。在全尺寸塔上进行了多次实验测量,Jordan、Wanger和Sargent等人提出了该参数的计算公式。然而,使用这些关系计算的浪涌阻抗值彼此之间的一致性很差,并且通常与各种测量值不一致。本文提出了利用电磁瞬变程序(EMTP)确定塔浪涌阻抗的非均匀分布参数的仿真模型。结果表明,所得到的数值较好地描述了输电线路遭雷击时塔的响应,塔的浪涌阻抗模拟值与实际测试值接近,相对误差为10%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The simulation model for calculating the surge impedance of a tower
Tower surge impedance is an important parameter in the prediction of HV and EHV lightning outage rates. Several attempts have been made to measure it experimentally on full scale towers, and formulas to calculate this parameter have been proposed by Jordan, Wanger and Sargent, etc. However, the values of surge impedance calculated using these relationships are in poor agreement with each other and, in general, with the various measured values. This paper presents a simulation model of uneven distributing parameter for determining the surge impedance of towers by the Electromagnetic Transients Program (EMTP). This paper also demonstrates that the values so obtained describe the response of the tower adequately when a transmission line is struck by lightning, Furthermore, the simulation value of tower surge impedance is close to the actual test value and the relative error is ten percent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信