{"title":"减少AC-DC-AC变换器的排放,改善输电网行为","authors":"P. Nicolae, I. Nicolae, G. Mihai, I. Pătru","doi":"10.1109/ISEMC.2014.6898958","DOIUrl":null,"url":null,"abstract":"The paper deals with specific matters concerning the electromagnetic disturbances introduced in an a.c. network by a static converter. A short description of the electronic converter AC-DC-AC of 1,500 W submitted to analysis is provided. The introduced disturbances are determined and analyzed considering the standard EN 50121-3-2. The disturbances transmitted through conducted emissions along the 1st phase and radiated emissions in the absence of anti-disturbances measures are represented. The conducted emissions for input and output ports are analyzed. Due to the influence of the PDN (Power Delivery Network), anti-disturbance measures were re-designed, details and discussions considering them being provided. Data concerning on the manufacturing of the new equipment including anti-disturbance measures are given. The equipment was tested considering the anti-disturbance measures and results are presented. They are complaint with EN 50121-3-2 Standard and with customer's requests.","PeriodicalId":279929,"journal":{"name":"2014 IEEE International Symposium on Electromagnetic Compatibility (EMC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Reducing emissions from an AC-DC-AC converter to improve Power Delivery Network behavior\",\"authors\":\"P. Nicolae, I. Nicolae, G. Mihai, I. Pătru\",\"doi\":\"10.1109/ISEMC.2014.6898958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with specific matters concerning the electromagnetic disturbances introduced in an a.c. network by a static converter. A short description of the electronic converter AC-DC-AC of 1,500 W submitted to analysis is provided. The introduced disturbances are determined and analyzed considering the standard EN 50121-3-2. The disturbances transmitted through conducted emissions along the 1st phase and radiated emissions in the absence of anti-disturbances measures are represented. The conducted emissions for input and output ports are analyzed. Due to the influence of the PDN (Power Delivery Network), anti-disturbance measures were re-designed, details and discussions considering them being provided. Data concerning on the manufacturing of the new equipment including anti-disturbance measures are given. The equipment was tested considering the anti-disturbance measures and results are presented. They are complaint with EN 50121-3-2 Standard and with customer's requests.\",\"PeriodicalId\":279929,\"journal\":{\"name\":\"2014 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2014.6898958\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Symposium on Electromagnetic Compatibility (EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2014.6898958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reducing emissions from an AC-DC-AC converter to improve Power Delivery Network behavior
The paper deals with specific matters concerning the electromagnetic disturbances introduced in an a.c. network by a static converter. A short description of the electronic converter AC-DC-AC of 1,500 W submitted to analysis is provided. The introduced disturbances are determined and analyzed considering the standard EN 50121-3-2. The disturbances transmitted through conducted emissions along the 1st phase and radiated emissions in the absence of anti-disturbances measures are represented. The conducted emissions for input and output ports are analyzed. Due to the influence of the PDN (Power Delivery Network), anti-disturbance measures were re-designed, details and discussions considering them being provided. Data concerning on the manufacturing of the new equipment including anti-disturbance measures are given. The equipment was tested considering the anti-disturbance measures and results are presented. They are complaint with EN 50121-3-2 Standard and with customer's requests.