基于PSS/E的沙捞越电网暂态稳定分析

Arfah Marini Mohamad, N. Hashim, N. Hamzah, N. F. Nik Ismail, M. F. Abdul Latip
{"title":"基于PSS/E的沙捞越电网暂态稳定分析","authors":"Arfah Marini Mohamad, N. Hashim, N. Hamzah, N. F. Nik Ismail, M. F. Abdul Latip","doi":"10.1109/ISIEA.2011.6108766","DOIUrl":null,"url":null,"abstract":"Transient stability analysis has become one of the major analyses in the power system to ensure the system stability to withstand a major disturbance. The effect of transient occurrence can lead to malfunction of electronic control equipment. Transient analysis can be conducted using simulation software package. One of the commercial simulation software package that used by industry worldwide is Siemens Power System Simulation for Engineering (PSS/E). This research paper highlights the usage of PSS/E to analyze Sarawak's Grid System stability using the simplest dynamic model that has been embedded into the program. To observe transient analysis using PSS/E, basic machine model such as generator, exciter and governor were used by varying default data in the program to find the best simulation output. This paper also analyzed the theory of critical clearing time (CCT) of fault occurrence between a transmission line near to the generator and far from the generator. CCT appears to be lesser when the fault occurs at a transmission line near to the generator. On the contrary, when fault occurs far from the generator, the duration of CCT is greater. The stability of the system is observed based on the machine rotor angle, machine speed, output electrical power and terminal voltage.","PeriodicalId":110449,"journal":{"name":"2011 IEEE Symposium on Industrial Electronics and Applications","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":"{\"title\":\"Transient stability analysis on Sarawak's Grid using Power System Simulator for Engineering (PSS/E)\",\"authors\":\"Arfah Marini Mohamad, N. Hashim, N. Hamzah, N. F. Nik Ismail, M. F. Abdul Latip\",\"doi\":\"10.1109/ISIEA.2011.6108766\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient stability analysis has become one of the major analyses in the power system to ensure the system stability to withstand a major disturbance. The effect of transient occurrence can lead to malfunction of electronic control equipment. Transient analysis can be conducted using simulation software package. One of the commercial simulation software package that used by industry worldwide is Siemens Power System Simulation for Engineering (PSS/E). This research paper highlights the usage of PSS/E to analyze Sarawak's Grid System stability using the simplest dynamic model that has been embedded into the program. To observe transient analysis using PSS/E, basic machine model such as generator, exciter and governor were used by varying default data in the program to find the best simulation output. This paper also analyzed the theory of critical clearing time (CCT) of fault occurrence between a transmission line near to the generator and far from the generator. CCT appears to be lesser when the fault occurs at a transmission line near to the generator. On the contrary, when fault occurs far from the generator, the duration of CCT is greater. The stability of the system is observed based on the machine rotor angle, machine speed, output electrical power and terminal voltage.\",\"PeriodicalId\":110449,\"journal\":{\"name\":\"2011 IEEE Symposium on Industrial Electronics and Applications\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Symposium on Industrial Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIEA.2011.6108766\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Symposium on Industrial Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIEA.2011.6108766","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

摘要

暂态稳定分析已成为电力系统中保证系统稳定承受大扰动的主要分析内容之一。瞬态发生的影响会导致电子控制设备的故障。利用仿真软件包进行瞬态分析。西门子电力系统工程仿真(PSS/E)是全球工业使用的商业仿真软件包之一。本研究论文强调使用PSS/E来分析沙捞越的电网系统稳定性,使用最简单的动态模型嵌入到程序中。为了观察PSS/E的暂态分析,通过改变程序中的默认数据,使用发电机、励磁机和调速器等基本机器模型来寻找最佳模拟输出。本文还分析了离发电机近和离发电机远的输电线路发生故障的临界清除时间理论。当故障发生在靠近发电机的传输线上时,CCT似乎较小。相反,当故障发生在远离发电机的地方时,CCT的持续时间更长。根据电机转子角度、电机转速、输出电功率和端电压观察系统的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient stability analysis on Sarawak's Grid using Power System Simulator for Engineering (PSS/E)
Transient stability analysis has become one of the major analyses in the power system to ensure the system stability to withstand a major disturbance. The effect of transient occurrence can lead to malfunction of electronic control equipment. Transient analysis can be conducted using simulation software package. One of the commercial simulation software package that used by industry worldwide is Siemens Power System Simulation for Engineering (PSS/E). This research paper highlights the usage of PSS/E to analyze Sarawak's Grid System stability using the simplest dynamic model that has been embedded into the program. To observe transient analysis using PSS/E, basic machine model such as generator, exciter and governor were used by varying default data in the program to find the best simulation output. This paper also analyzed the theory of critical clearing time (CCT) of fault occurrence between a transmission line near to the generator and far from the generator. CCT appears to be lesser when the fault occurs at a transmission line near to the generator. On the contrary, when fault occurs far from the generator, the duration of CCT is greater. The stability of the system is observed based on the machine rotor angle, machine speed, output electrical power and terminal voltage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信