表面发生可逆电化学反应时平面伏安电极的时域计量特性

Krzysztof Suchocki
{"title":"表面发生可逆电化学反应时平面伏安电极的时域计量特性","authors":"Krzysztof Suchocki","doi":"10.1117/12.2248337","DOIUrl":null,"url":null,"abstract":"The study deals with metrological characteristics of the flat voltammetric electrode used for determination of ions concentration by the DC voltammetric method, where a reversible reaction of electrochemical oxidation/reduction takes place on the surface. The analysis shows that such voltammetric electrode acts as a transducer of the first order, where the input signal is a concentration of marked ions in tested solution and the output signal is the current associated with a reversible reaction of oxidation / reduction. Metrological characteristics of such electrode in the time domain are determined by its sensitivity and time constant. The values of these parameters are defined by measurements of characteristics of the voltammetric electrode, polarization voltage and marked ions. To determine the effect of a particular volume of each of these parameters several numerical simulations are presented.","PeriodicalId":101814,"journal":{"name":"Scientific Conference on Optical and Electronic Sensors","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Metrological characteristics of the flat voltammetric electrode in time domain with a reversible electrochemical reaction running on the surface\",\"authors\":\"Krzysztof Suchocki\",\"doi\":\"10.1117/12.2248337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study deals with metrological characteristics of the flat voltammetric electrode used for determination of ions concentration by the DC voltammetric method, where a reversible reaction of electrochemical oxidation/reduction takes place on the surface. The analysis shows that such voltammetric electrode acts as a transducer of the first order, where the input signal is a concentration of marked ions in tested solution and the output signal is the current associated with a reversible reaction of oxidation / reduction. Metrological characteristics of such electrode in the time domain are determined by its sensitivity and time constant. The values of these parameters are defined by measurements of characteristics of the voltammetric electrode, polarization voltage and marked ions. To determine the effect of a particular volume of each of these parameters several numerical simulations are presented.\",\"PeriodicalId\":101814,\"journal\":{\"name\":\"Scientific Conference on Optical and Electronic Sensors\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scientific Conference on Optical and Electronic Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2248337\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific Conference on Optical and Electronic Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2248337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究讨论了用直流伏安法测定离子浓度的平伏安电极的计量特性,其中电化学氧化/还原的可逆反应发生在表面。分析表明,这种伏安电极作为一阶换能器,其输入信号是被测溶液中标记离子的浓度,输出信号是与氧化/还原可逆反应相关的电流。该电极的时域计量特性由其灵敏度和时间常数决定。这些参数的值是通过测量伏安电极的特性、极化电压和标记离子来确定的。为了确定这些参数中每个特定体积的影响,提出了几个数值模拟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Metrological characteristics of the flat voltammetric electrode in time domain with a reversible electrochemical reaction running on the surface
The study deals with metrological characteristics of the flat voltammetric electrode used for determination of ions concentration by the DC voltammetric method, where a reversible reaction of electrochemical oxidation/reduction takes place on the surface. The analysis shows that such voltammetric electrode acts as a transducer of the first order, where the input signal is a concentration of marked ions in tested solution and the output signal is the current associated with a reversible reaction of oxidation / reduction. Metrological characteristics of such electrode in the time domain are determined by its sensitivity and time constant. The values of these parameters are defined by measurements of characteristics of the voltammetric electrode, polarization voltage and marked ions. To determine the effect of a particular volume of each of these parameters several numerical simulations are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信