高脉冲率刺激人工耳蜗的潜在优势

B. Lithgow
{"title":"高脉冲率刺激人工耳蜗的潜在优势","authors":"B. Lithgow","doi":"10.1109/ICBEM.1998.666396","DOIUrl":null,"url":null,"abstract":"Lower thresholds and smaller stimulus currents may allow for the use of smaller cochlear implant stimulus electrodes and potentially more channels of stimulation within a given cochlea region. With high (2 kpps) compared to low (125 pps) pulse rate stimuli, inferior colliculus (IC) units have a significantly lower stimulus threshold. The provision of a background \"spontaneous\" stimuli may provide, a further decrease in threshold current, a unit population with a larger range of thresholds and a more physiologically natural stimulus response. A low threshold, low current level, high pulse rate processing strategy capable of evoking background \"spontaneous\" firing in units is described. This background stimulus strategy has the potential to deliver more speech information to cochlear implant patients.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Potential advantages of high pulse rate stimulation of cochlear implants\",\"authors\":\"B. Lithgow\",\"doi\":\"10.1109/ICBEM.1998.666396\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lower thresholds and smaller stimulus currents may allow for the use of smaller cochlear implant stimulus electrodes and potentially more channels of stimulation within a given cochlea region. With high (2 kpps) compared to low (125 pps) pulse rate stimuli, inferior colliculus (IC) units have a significantly lower stimulus threshold. The provision of a background \\\"spontaneous\\\" stimuli may provide, a further decrease in threshold current, a unit population with a larger range of thresholds and a more physiologically natural stimulus response. A low threshold, low current level, high pulse rate processing strategy capable of evoking background \\\"spontaneous\\\" firing in units is described. This background stimulus strategy has the potential to deliver more speech information to cochlear implant patients.\",\"PeriodicalId\":213764,\"journal\":{\"name\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBEM.1998.666396\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEM.1998.666396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

较低的阈值和较小的刺激电流可能允许使用更小的人工耳蜗刺激电极和在给定耳蜗区域内潜在的更多的刺激通道。高(2 kpps)与低(125 kpps)脉冲刺激相比,下丘(IC)单位具有明显较低的刺激阈值。提供背景“自发”刺激可以提供阈值电流进一步降低,阈值范围更大的单位群和生理上更自然的刺激反应。描述了一种低阈值,低电流水平,高脉冲率处理策略,能够在单位中唤起背景“自发”放电。这种背景刺激策略有可能为人工耳蜗患者提供更多的语音信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Potential advantages of high pulse rate stimulation of cochlear implants
Lower thresholds and smaller stimulus currents may allow for the use of smaller cochlear implant stimulus electrodes and potentially more channels of stimulation within a given cochlea region. With high (2 kpps) compared to low (125 pps) pulse rate stimuli, inferior colliculus (IC) units have a significantly lower stimulus threshold. The provision of a background "spontaneous" stimuli may provide, a further decrease in threshold current, a unit population with a larger range of thresholds and a more physiologically natural stimulus response. A low threshold, low current level, high pulse rate processing strategy capable of evoking background "spontaneous" firing in units is described. This background stimulus strategy has the potential to deliver more speech information to cochlear implant patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信