{"title":"安全、可靠、高效——超越电网边缘","authors":"H. Borland, M. Mccormack","doi":"10.1109/GridEdge54130.2023.10102704","DOIUrl":null,"url":null,"abstract":"Regardless of how the Grid Edge is perceived, grid users and the society it serves, demand a grid that is safe, reliable and efficient. This goes far beyond the physical ‘grid edge’ and permeates the totality of the distribution system in particular. Earth faults at Medium Voltage have a great impact on safety and reliability. In this paper, the selection of compensated neutral treatment is shown to provide optimized performance. Augmentation with Faulted Phase Earthing or Augmented Residual Current Compensation adds further to the safety performance. This is advantageous in high-risk areas and in wildfire mitigation. Efficiency in returning supply to customers after outages is addressed, including the use of Synchronised Line Monitoring. This paper presents fundamental solutions to deliver safety, reliability and efficiency at and beyond the Grid Edge.","PeriodicalId":377998,"journal":{"name":"2023 IEEE PES Grid Edge Technologies Conference & Exposition (Grid Edge)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safety, Reliability and Efficiency – beyond the grid edge\",\"authors\":\"H. Borland, M. Mccormack\",\"doi\":\"10.1109/GridEdge54130.2023.10102704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Regardless of how the Grid Edge is perceived, grid users and the society it serves, demand a grid that is safe, reliable and efficient. This goes far beyond the physical ‘grid edge’ and permeates the totality of the distribution system in particular. Earth faults at Medium Voltage have a great impact on safety and reliability. In this paper, the selection of compensated neutral treatment is shown to provide optimized performance. Augmentation with Faulted Phase Earthing or Augmented Residual Current Compensation adds further to the safety performance. This is advantageous in high-risk areas and in wildfire mitigation. Efficiency in returning supply to customers after outages is addressed, including the use of Synchronised Line Monitoring. This paper presents fundamental solutions to deliver safety, reliability and efficiency at and beyond the Grid Edge.\",\"PeriodicalId\":377998,\"journal\":{\"name\":\"2023 IEEE PES Grid Edge Technologies Conference & Exposition (Grid Edge)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE PES Grid Edge Technologies Conference & Exposition (Grid Edge)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GridEdge54130.2023.10102704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE PES Grid Edge Technologies Conference & Exposition (Grid Edge)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GridEdge54130.2023.10102704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

不管人们如何看待网格边缘,电网用户和它所服务的社会都需要一个安全、可靠和高效的电网。这远远超出了物理的“电网边缘”,特别是渗透到整个配电系统。中压接地故障对设备的安全可靠性有很大的影响。在本文中,选择补偿中性处理可以提供最佳的性能。采用故障相接地或增强剩余电流补偿的增强电路进一步提高了安全性能。这在高风险地区和缓解野火方面是有利的。解决了在停电后向客户恢复供电的效率问题,包括使用同步线路监控。本文提出了在网格边缘及边缘之外提供安全性、可靠性和效率的基本解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Safety, Reliability and Efficiency – beyond the grid edge
Regardless of how the Grid Edge is perceived, grid users and the society it serves, demand a grid that is safe, reliable and efficient. This goes far beyond the physical ‘grid edge’ and permeates the totality of the distribution system in particular. Earth faults at Medium Voltage have a great impact on safety and reliability. In this paper, the selection of compensated neutral treatment is shown to provide optimized performance. Augmentation with Faulted Phase Earthing or Augmented Residual Current Compensation adds further to the safety performance. This is advantageous in high-risk areas and in wildfire mitigation. Efficiency in returning supply to customers after outages is addressed, including the use of Synchronised Line Monitoring. This paper presents fundamental solutions to deliver safety, reliability and efficiency at and beyond the Grid Edge.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信