{"title":"多束OCT的理论与应用","authors":"J. Holmes","doi":"10.1117/12.821006","DOIUrl":null,"url":null,"abstract":"The lateral resolution of Fourier domain optical coherence tomography (FD-OCT) systems is limited by the depth of focus that can be achieved over the desired imaging depth at the chosen wavelength. I present a solution in which multiple beams focused at different depths are scanned together, so that a mosaic image can be produced, with at least double the resolution possible from a single beam system. Side-benefits also arise from the ability to combine data from each beam to improve signal-to-noise. The theory of this approach is discussed, advantages, and also the practical realisation in a variety of ex-vivo and in-vivo OCT imaging probes, together with results from a number of applications.","PeriodicalId":184459,"journal":{"name":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","volume":"7139 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Theory and applications of multi-beam OCT\",\"authors\":\"J. Holmes\",\"doi\":\"10.1117/12.821006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The lateral resolution of Fourier domain optical coherence tomography (FD-OCT) systems is limited by the depth of focus that can be achieved over the desired imaging depth at the chosen wavelength. I present a solution in which multiple beams focused at different depths are scanned together, so that a mosaic image can be produced, with at least double the resolution possible from a single beam system. Side-benefits also arise from the ability to combine data from each beam to improve signal-to-noise. The theory of this approach is discussed, advantages, and also the practical realisation in a variety of ex-vivo and in-vivo OCT imaging probes, together with results from a number of applications.\",\"PeriodicalId\":184459,\"journal\":{\"name\":\"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics\",\"volume\":\"7139 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.821006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.821006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The lateral resolution of Fourier domain optical coherence tomography (FD-OCT) systems is limited by the depth of focus that can be achieved over the desired imaging depth at the chosen wavelength. I present a solution in which multiple beams focused at different depths are scanned together, so that a mosaic image can be produced, with at least double the resolution possible from a single beam system. Side-benefits also arise from the ability to combine data from each beam to improve signal-to-noise. The theory of this approach is discussed, advantages, and also the practical realisation in a variety of ex-vivo and in-vivo OCT imaging probes, together with results from a number of applications.