{"title":"印度喜马偕尔邦哈米尔普尔小学教室室内空气质量调查","authors":"V. Shree, Bhanu M. Marwaha, P. Awasthi","doi":"10.3126/HN.V24I0.23583","DOIUrl":null,"url":null,"abstract":"Two schools in Hamirpur (Himachal Pradesh, India) having hybrid ventilation (ceiling fan) were selected for indoor and outdoor air quality investigation. Investigated parameters include temperature, relative humidity, CO2, and PM2.5 for both indoor and outdoor air quality. The average concentrations of CO2, and PM2.5 are estimated for indoor and outdoor air quality. Result shows that adopted building performance is not good in comparison with designed ones. The indoor concentrations of various pollutants are found to be higher in comparison with outdoor, so there is an urgent need to reduce the levels of pollutants inside the primary classrooms.","PeriodicalId":137822,"journal":{"name":"Hydro Nepal: Journal of Water, Energy and Environment","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Indoor Air Quality Investigation at Primary Classrooms in Hamirpur, Himachal Pradesh, India\",\"authors\":\"V. Shree, Bhanu M. Marwaha, P. Awasthi\",\"doi\":\"10.3126/HN.V24I0.23583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two schools in Hamirpur (Himachal Pradesh, India) having hybrid ventilation (ceiling fan) were selected for indoor and outdoor air quality investigation. Investigated parameters include temperature, relative humidity, CO2, and PM2.5 for both indoor and outdoor air quality. The average concentrations of CO2, and PM2.5 are estimated for indoor and outdoor air quality. Result shows that adopted building performance is not good in comparison with designed ones. The indoor concentrations of various pollutants are found to be higher in comparison with outdoor, so there is an urgent need to reduce the levels of pollutants inside the primary classrooms.\",\"PeriodicalId\":137822,\"journal\":{\"name\":\"Hydro Nepal: Journal of Water, Energy and Environment\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hydro Nepal: Journal of Water, Energy and Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3126/HN.V24I0.23583\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hydro Nepal: Journal of Water, Energy and Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/HN.V24I0.23583","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Indoor Air Quality Investigation at Primary Classrooms in Hamirpur, Himachal Pradesh, India
Two schools in Hamirpur (Himachal Pradesh, India) having hybrid ventilation (ceiling fan) were selected for indoor and outdoor air quality investigation. Investigated parameters include temperature, relative humidity, CO2, and PM2.5 for both indoor and outdoor air quality. The average concentrations of CO2, and PM2.5 are estimated for indoor and outdoor air quality. Result shows that adopted building performance is not good in comparison with designed ones. The indoor concentrations of various pollutants are found to be higher in comparison with outdoor, so there is an urgent need to reduce the levels of pollutants inside the primary classrooms.