宽带调制信号的标量和矢量标定的比较研究

Shuw-Guann Lin, D. Chang, Y. Juang, H. Chiou
{"title":"宽带调制信号的标量和矢量标定的比较研究","authors":"Shuw-Guann Lin, D. Chang, Y. Juang, H. Chiou","doi":"10.1109/EUMC.2015.7346071","DOIUrl":null,"url":null,"abstract":"As generating the wideband modulation signals, the signal quality is usually degraded by many impairments such as I/Q path delay, non-flat RF frequency response and etc. In this paper, the authors propose two methods by using Keysight SystemVue™ to create the modulation signals and download them to an arbitrary waveform generator (AWG) for further calibration. To compare these two methods, a 64 QAM modulation waveform with a bandwidth over 1GHz was evaluated. The first method is multi-tone scalar calibration which improves the error vector magnitude (EVM) from 5.3 % to 4.2 %. The other one is vector calibration which improves the EVM from 5.3% to 1.1%. Finally, these signals are used to measure the system performance of an amplifier. As found, the modulation signal with vector calibration can show the more exact effect of AM/AM and AM/PM on EVM of the amplifier than scalar does.","PeriodicalId":376019,"journal":{"name":"2015 European Radar Conference (EuRAD)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison study of scalar and vector calibrations for wideband modulation signals\",\"authors\":\"Shuw-Guann Lin, D. Chang, Y. Juang, H. Chiou\",\"doi\":\"10.1109/EUMC.2015.7346071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As generating the wideband modulation signals, the signal quality is usually degraded by many impairments such as I/Q path delay, non-flat RF frequency response and etc. In this paper, the authors propose two methods by using Keysight SystemVue™ to create the modulation signals and download them to an arbitrary waveform generator (AWG) for further calibration. To compare these two methods, a 64 QAM modulation waveform with a bandwidth over 1GHz was evaluated. The first method is multi-tone scalar calibration which improves the error vector magnitude (EVM) from 5.3 % to 4.2 %. The other one is vector calibration which improves the EVM from 5.3% to 1.1%. Finally, these signals are used to measure the system performance of an amplifier. As found, the modulation signal with vector calibration can show the more exact effect of AM/AM and AM/PM on EVM of the amplifier than scalar does.\",\"PeriodicalId\":376019,\"journal\":{\"name\":\"2015 European Radar Conference (EuRAD)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 European Radar Conference (EuRAD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMC.2015.7346071\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 European Radar Conference (EuRAD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMC.2015.7346071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在产生宽带调制信号时,信号质量通常会受到I/Q路径延迟、非平坦射频频率响应等诸多缺陷的影响。在本文中,作者提出了两种方法,即使用Keysight SystemVue™创建调制信号并将其下载到任意波形发生器(AWG)以进行进一步校准。为了比较这两种方法,对带宽超过1GHz的64 QAM调制波形进行了评估。第一种方法是多音标量定标,将误差矢量幅度(EVM)从5.3%提高到4.2%。另一种是矢量校准,将EVM从5.3%提高到1.1%。最后,这些信号被用来测量放大器的系统性能。结果表明,与标量调制相比,矢量校准调制信号能更准确地显示调幅/调幅和调幅/调幅对放大器EVM的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison study of scalar and vector calibrations for wideband modulation signals
As generating the wideband modulation signals, the signal quality is usually degraded by many impairments such as I/Q path delay, non-flat RF frequency response and etc. In this paper, the authors propose two methods by using Keysight SystemVue™ to create the modulation signals and download them to an arbitrary waveform generator (AWG) for further calibration. To compare these two methods, a 64 QAM modulation waveform with a bandwidth over 1GHz was evaluated. The first method is multi-tone scalar calibration which improves the error vector magnitude (EVM) from 5.3 % to 4.2 %. The other one is vector calibration which improves the EVM from 5.3% to 1.1%. Finally, these signals are used to measure the system performance of an amplifier. As found, the modulation signal with vector calibration can show the more exact effect of AM/AM and AM/PM on EVM of the amplifier than scalar does.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信