{"title":"网络时间同步在一个安全的自动化网络","authors":"T. Novak, B. Sevcik","doi":"10.1109/WFCS.2008.4638717","DOIUrl":null,"url":null,"abstract":"Today there is a great request of using automation networks in safety critical environments. Thus, such systems used in industrial and building automation have been enhanced with safety features derived from strict safety requirements specified in IEC 61508. One of the safety requirements to be met is the detection of hazardous events on the network such as the delay of a message. A safety measure to identify these hazardous events is the use of a timestamp within a safe protocol. However, a common time base among the nodes must be provided - by means of a network time synchronization mechanism. A centralized and decentralized approach was developed within the SafetyLon project. Realization of the concept and implementation in the producer/consumer model of SafetyLon is outlined.","PeriodicalId":352963,"journal":{"name":"2008 IEEE International Workshop on Factory Communication Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Network time synchronization in a safe automation network\",\"authors\":\"T. Novak, B. Sevcik\",\"doi\":\"10.1109/WFCS.2008.4638717\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Today there is a great request of using automation networks in safety critical environments. Thus, such systems used in industrial and building automation have been enhanced with safety features derived from strict safety requirements specified in IEC 61508. One of the safety requirements to be met is the detection of hazardous events on the network such as the delay of a message. A safety measure to identify these hazardous events is the use of a timestamp within a safe protocol. However, a common time base among the nodes must be provided - by means of a network time synchronization mechanism. A centralized and decentralized approach was developed within the SafetyLon project. Realization of the concept and implementation in the producer/consumer model of SafetyLon is outlined.\",\"PeriodicalId\":352963,\"journal\":{\"name\":\"2008 IEEE International Workshop on Factory Communication Systems\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE International Workshop on Factory Communication Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WFCS.2008.4638717\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE International Workshop on Factory Communication Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WFCS.2008.4638717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

如今,在安全关键环境中使用自动化网络的需求很大。因此,在工业和楼宇自动化中使用的此类系统已经增强了来自IEC 61508规定的严格安全要求的安全功能。要满足的安全要求之一是检测网络上的危险事件,例如消息延迟。识别这些危险事件的安全措施是在安全协议中使用时间戳。但是,必须通过网络时间同步机制提供节点之间的公共时基。在SafetyLon项目中开发了一种集中和分散的方法。在SafetyLon的生产者/消费者模型中概述了概念的实现和实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Network time synchronization in a safe automation network
Today there is a great request of using automation networks in safety critical environments. Thus, such systems used in industrial and building automation have been enhanced with safety features derived from strict safety requirements specified in IEC 61508. One of the safety requirements to be met is the detection of hazardous events on the network such as the delay of a message. A safety measure to identify these hazardous events is the use of a timestamp within a safe protocol. However, a common time base among the nodes must be provided - by means of a network time synchronization mechanism. A centralized and decentralized approach was developed within the SafetyLon project. Realization of the concept and implementation in the producer/consumer model of SafetyLon is outlined.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信