{"title":"夏季温室瞬时热损失效率系数","authors":"R. Sutar, G. Tiwari","doi":"10.1080/01425919508914305","DOIUrl":null,"url":null,"abstract":"In this technical note, an attempt has been made to develop an analytical expression for an instantaneous thermal loss efficiency factor for a summer greenhouse. The analysis is based on energy balance equations for each component of the greenhouse in a steady state condition. Effect of design and climatic parameters have also been taken into account. An ideal condition has been achieved analytically, for a best summer greenhouse. The nature of characteristic curve obtained by the present model has been compared with the experimental results obtained by others.","PeriodicalId":162029,"journal":{"name":"International Journal of Solar Energy","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"INSTANTANEOUS THERMAL LOSS EFFICIENCY FACTOR FOR SUMMER GREENHOUSE\",\"authors\":\"R. Sutar, G. Tiwari\",\"doi\":\"10.1080/01425919508914305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this technical note, an attempt has been made to develop an analytical expression for an instantaneous thermal loss efficiency factor for a summer greenhouse. The analysis is based on energy balance equations for each component of the greenhouse in a steady state condition. Effect of design and climatic parameters have also been taken into account. An ideal condition has been achieved analytically, for a best summer greenhouse. The nature of characteristic curve obtained by the present model has been compared with the experimental results obtained by others.\",\"PeriodicalId\":162029,\"journal\":{\"name\":\"International Journal of Solar Energy\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Solar Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/01425919508914305\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Solar Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/01425919508914305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
INSTANTANEOUS THERMAL LOSS EFFICIENCY FACTOR FOR SUMMER GREENHOUSE
In this technical note, an attempt has been made to develop an analytical expression for an instantaneous thermal loss efficiency factor for a summer greenhouse. The analysis is based on energy balance equations for each component of the greenhouse in a steady state condition. Effect of design and climatic parameters have also been taken into account. An ideal condition has been achieved analytically, for a best summer greenhouse. The nature of characteristic curve obtained by the present model has been compared with the experimental results obtained by others.