串联补偿线路功率摆幅故障检测

P. K. Nayak, A. Pradhan, P. Bajpai
{"title":"串联补偿线路功率摆幅故障检测","authors":"P. K. Nayak, A. Pradhan, P. Bajpai","doi":"10.1109/ICEAS.2011.6147076","DOIUrl":null,"url":null,"abstract":"The apparent impedance seen by a distance relay may fall within its operating zone during power swing. This may cause the relay to trip unnecessarily. To avoid unintended trip operation during such conditions, a power swing blocking function is utilized in distance relays. However, if a fault occurs during power swing, the relay should detect the fault and trip as soon as possible for maintaining security. Detection of fault during power swing in a series compensated line is more complicated due to the presence of protection circuit of the capacitor. This paper proposes a negative sequence current based technique for detecting fault during power swing in a series compensated line. The technique is tested for symmetrical and unsymmetrical faults in a system simulated through EMTDC/PSCAD. The method is compared with available techniques.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Detecting fault during power swing for a series compensated line\",\"authors\":\"P. K. Nayak, A. Pradhan, P. Bajpai\",\"doi\":\"10.1109/ICEAS.2011.6147076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The apparent impedance seen by a distance relay may fall within its operating zone during power swing. This may cause the relay to trip unnecessarily. To avoid unintended trip operation during such conditions, a power swing blocking function is utilized in distance relays. However, if a fault occurs during power swing, the relay should detect the fault and trip as soon as possible for maintaining security. Detection of fault during power swing in a series compensated line is more complicated due to the presence of protection circuit of the capacitor. This paper proposes a negative sequence current based technique for detecting fault during power swing in a series compensated line. The technique is tested for symmetrical and unsymmetrical faults in a system simulated through EMTDC/PSCAD. The method is compared with available techniques.\",\"PeriodicalId\":273164,\"journal\":{\"name\":\"2011 International Conference on Energy, Automation and Signal\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Energy, Automation and Signal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEAS.2011.6147076\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

在功率摆动期间,距离继电器所看到的视阻抗可能落在其工作区域内。这可能导致继电器不必要地跳闸。在这种情况下,为了避免意外的跳闸操作,在距离继电器中使用了功率摆动阻塞功能。但是,如果在功率摆动过程中发生故障,继电器应尽快检测故障并跳闸,以维护安全。在串联补偿线路中,由于电容保护电路的存在,使得功率摆幅故障的检测更加复杂。提出了一种基于负序电流的串联补偿线路功率摆动故障检测技术。在EMTDC/PSCAD仿真系统中,对该技术进行了对称和非对称故障的测试。并将该方法与现有技术进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detecting fault during power swing for a series compensated line
The apparent impedance seen by a distance relay may fall within its operating zone during power swing. This may cause the relay to trip unnecessarily. To avoid unintended trip operation during such conditions, a power swing blocking function is utilized in distance relays. However, if a fault occurs during power swing, the relay should detect the fault and trip as soon as possible for maintaining security. Detection of fault during power swing in a series compensated line is more complicated due to the presence of protection circuit of the capacitor. This paper proposes a negative sequence current based technique for detecting fault during power swing in a series compensated line. The technique is tested for symmetrical and unsymmetrical faults in a system simulated through EMTDC/PSCAD. The method is compared with available techniques.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信