{"title":"使用多波长复用的超分辨率无透镜显微镜","authors":"Xuejuan Wu, Jialin Zhang, Jiasong Sun, Linpeng Lu, Qian Chen, C. Zuo","doi":"10.1117/12.2586569","DOIUrl":null,"url":null,"abstract":"We report a multi-wavelength multiplexed setup and associated super-resolution reconstruction method in lensless microscopy, which can generate high-resolution reconstructions from undersampled raw measurements captured at multiple wavelengths. The reconstruction result of the Benchmark Quantitative Phase Microscopy Target (QPTTM) demonstrates the resolution enhancement quantitatively, which achieves a half-pitch lateral resolution of 691 nm across a large field of view (~29.85 mm2), surpassing 2.41 times of the theoretical NyquistShannon sampling resolution limit imposed by the pixel-size of the sensor (1.67 µm). Compared with other superresolution methods such as lateral or axial shift-based device and illumination source rotation design, wavelength multiplexed avoids the need for shifting/rotating mechanical components. This multi-wavelength multiplexed super-resolution method would benet the research and development of a more stable lensless microscopy system.","PeriodicalId":370739,"journal":{"name":"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Super-resolution lensless microscopy using multi-wavelength multiplexing\",\"authors\":\"Xuejuan Wu, Jialin Zhang, Jiasong Sun, Linpeng Lu, Qian Chen, C. Zuo\",\"doi\":\"10.1117/12.2586569\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report a multi-wavelength multiplexed setup and associated super-resolution reconstruction method in lensless microscopy, which can generate high-resolution reconstructions from undersampled raw measurements captured at multiple wavelengths. The reconstruction result of the Benchmark Quantitative Phase Microscopy Target (QPTTM) demonstrates the resolution enhancement quantitatively, which achieves a half-pitch lateral resolution of 691 nm across a large field of view (~29.85 mm2), surpassing 2.41 times of the theoretical NyquistShannon sampling resolution limit imposed by the pixel-size of the sensor (1.67 µm). Compared with other superresolution methods such as lateral or axial shift-based device and illumination source rotation design, wavelength multiplexed avoids the need for shifting/rotating mechanical components. This multi-wavelength multiplexed super-resolution method would benet the research and development of a more stable lensless microscopy system.\",\"PeriodicalId\":370739,\"journal\":{\"name\":\"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2586569\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2586569","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Super-resolution lensless microscopy using multi-wavelength multiplexing
We report a multi-wavelength multiplexed setup and associated super-resolution reconstruction method in lensless microscopy, which can generate high-resolution reconstructions from undersampled raw measurements captured at multiple wavelengths. The reconstruction result of the Benchmark Quantitative Phase Microscopy Target (QPTTM) demonstrates the resolution enhancement quantitatively, which achieves a half-pitch lateral resolution of 691 nm across a large field of view (~29.85 mm2), surpassing 2.41 times of the theoretical NyquistShannon sampling resolution limit imposed by the pixel-size of the sensor (1.67 µm). Compared with other superresolution methods such as lateral or axial shift-based device and illumination source rotation design, wavelength multiplexed avoids the need for shifting/rotating mechanical components. This multi-wavelength multiplexed super-resolution method would benet the research and development of a more stable lensless microscopy system.