提高了农村电力用户的服务可靠性——创新了一次电源互连丢失后的自动恢复

J. W. Rice, S. Fulford, N. Seeley
{"title":"提高了农村电力用户的服务可靠性——创新了一次电源互连丢失后的自动恢复","authors":"J. W. Rice, S. Fulford, N. Seeley","doi":"10.1109/PSAMP.2007.4740899","DOIUrl":null,"url":null,"abstract":"Plumas-Sierra Rural Electric Cooperative (PSREC) has two interconnections with large investor-owned electric utilities. Presently, PSREC normally operates solely connected to the Pacific Gas and Electric (PG&E) system via a radially fed line. This connection to PG&E is subject to service interruption for events on the PG&E line or connecting facility. Loss of this PG&E interconnection drops the entire PSREC customer load. An alternative service interconnection is available with Sierra Pacific Power Company (SPPCo) on another part of the system. However, this alternative source does not have the capacity to carry the entire PSREC customer load. In an effort to increase the reliability of PSREC's service to its customers, future enhancements will allow the system to operate with PG&E and SPPCo in parallel, a project PSREC dubbed Marble Live. In addition, PSREC decided to implement an auto- restoration scheme based on scenarios that require PG&E to interrupt service to the PSREC system. In the case of an event on the PG&E line, PSREC will automatically island its system and execute a series of steps to reconnect to PG&E, should conditions permit, or remain disconnected from PG&E and connect to SPPCo after shedding the appropriate amount of load. This paper describes the system protection and control scheme solution that PSREC incorporated to accomplish a system restoration that satisfies the demands of both PG&E and SPPCo while increasing the reliability of service to PSREC's customers. Audio tone direct transfer trip equipment, IEC 61850 GSSE, also known as UCA GOOSE, messages among geographically diverse locations, and spread-spectrum radio among directional relays provide communication among substations, while the restoration logic resides in communications processors at each substation. The combination of protection elements and communications equipment initiates selective load shedding and restores power from the alternate power source to as many retail customers as possible.","PeriodicalId":114949,"journal":{"name":"2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Improved service reliability for rural electric customers - innovative auto-restoration following loss of primary source interconnection\",\"authors\":\"J. W. Rice, S. Fulford, N. Seeley\",\"doi\":\"10.1109/PSAMP.2007.4740899\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Plumas-Sierra Rural Electric Cooperative (PSREC) has two interconnections with large investor-owned electric utilities. Presently, PSREC normally operates solely connected to the Pacific Gas and Electric (PG&E) system via a radially fed line. This connection to PG&E is subject to service interruption for events on the PG&E line or connecting facility. Loss of this PG&E interconnection drops the entire PSREC customer load. An alternative service interconnection is available with Sierra Pacific Power Company (SPPCo) on another part of the system. However, this alternative source does not have the capacity to carry the entire PSREC customer load. In an effort to increase the reliability of PSREC's service to its customers, future enhancements will allow the system to operate with PG&E and SPPCo in parallel, a project PSREC dubbed Marble Live. In addition, PSREC decided to implement an auto- restoration scheme based on scenarios that require PG&E to interrupt service to the PSREC system. In the case of an event on the PG&E line, PSREC will automatically island its system and execute a series of steps to reconnect to PG&E, should conditions permit, or remain disconnected from PG&E and connect to SPPCo after shedding the appropriate amount of load. This paper describes the system protection and control scheme solution that PSREC incorporated to accomplish a system restoration that satisfies the demands of both PG&E and SPPCo while increasing the reliability of service to PSREC's customers. Audio tone direct transfer trip equipment, IEC 61850 GSSE, also known as UCA GOOSE, messages among geographically diverse locations, and spread-spectrum radio among directional relays provide communication among substations, while the restoration logic resides in communications processors at each substation. The combination of protection elements and communications equipment initiates selective load shedding and restores power from the alternate power source to as many retail customers as possible.\",\"PeriodicalId\":114949,\"journal\":{\"name\":\"2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PSAMP.2007.4740899\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSAMP.2007.4740899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

普拉马斯-塞拉农村电力合作社(PSREC)与大型投资者拥有的电力公司有两个互联。目前,PSREC通常通过径向馈线与太平洋天然气和电力公司(PG&E)系统单独连接。此与PG&E的连接可能会因PG&E线路或连接设施的事件而中断服务。这种PG&E互连的损失降低了整个PSREC客户负载。在系统的另一部分,可与Sierra Pacific Power Company (SPPCo)进行替代服务互连。但是,这种替代源不具备承载整个PSREC客户负载的能力。为了提高PSREC向客户提供服务的可靠性,未来的改进将使该系统能够与PG&E和SPPCo并行运行,PSREC将该项目称为Marble Live。此外,PSREC决定根据需要PG&E中断PSREC系统服务的场景实施自动恢复方案。在PG&E线路上发生事件的情况下,PSREC将自动隔离其系统并执行一系列步骤重新连接PG&E,如果条件允许,或保持与PG&E断开连接,并在减少适当的负载后连接到SPPCo。本文介绍了PSREC采用的系统保护和控制方案解决方案,以实现系统恢复,满足PG&E和SPPCo的需求,同时提高PSREC客户的服务可靠性。音频音直接传输跳闸设备,IEC 61850 GSSE,也称为UCA GOOSE,地理位置不同的消息和定向中继之间的扩频无线电提供变电站之间的通信,而恢复逻辑驻留在每个变电站的通信处理器中。保护元件和通信设备的组合启动选择性负载减少,并从备用电源恢复电力给尽可能多的零售客户。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improved service reliability for rural electric customers - innovative auto-restoration following loss of primary source interconnection
Plumas-Sierra Rural Electric Cooperative (PSREC) has two interconnections with large investor-owned electric utilities. Presently, PSREC normally operates solely connected to the Pacific Gas and Electric (PG&E) system via a radially fed line. This connection to PG&E is subject to service interruption for events on the PG&E line or connecting facility. Loss of this PG&E interconnection drops the entire PSREC customer load. An alternative service interconnection is available with Sierra Pacific Power Company (SPPCo) on another part of the system. However, this alternative source does not have the capacity to carry the entire PSREC customer load. In an effort to increase the reliability of PSREC's service to its customers, future enhancements will allow the system to operate with PG&E and SPPCo in parallel, a project PSREC dubbed Marble Live. In addition, PSREC decided to implement an auto- restoration scheme based on scenarios that require PG&E to interrupt service to the PSREC system. In the case of an event on the PG&E line, PSREC will automatically island its system and execute a series of steps to reconnect to PG&E, should conditions permit, or remain disconnected from PG&E and connect to SPPCo after shedding the appropriate amount of load. This paper describes the system protection and control scheme solution that PSREC incorporated to accomplish a system restoration that satisfies the demands of both PG&E and SPPCo while increasing the reliability of service to PSREC's customers. Audio tone direct transfer trip equipment, IEC 61850 GSSE, also known as UCA GOOSE, messages among geographically diverse locations, and spread-spectrum radio among directional relays provide communication among substations, while the restoration logic resides in communications processors at each substation. The combination of protection elements and communications equipment initiates selective load shedding and restores power from the alternate power source to as many retail customers as possible.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信