风力发电机组双馈感应发电机的无源控制

I. López-García, V. M. Jimenez-Mondragon, E. Campero-Littlewood, G. Espinosa-Pérez
{"title":"风力发电机组双馈感应发电机的无源控制","authors":"I. López-García, V. M. Jimenez-Mondragon, E. Campero-Littlewood, G. Espinosa-Pérez","doi":"10.1109/CERMA.2010.125","DOIUrl":null,"url":null,"abstract":"This paper presents the evaluation of a passivity based control (PBC) strategy for doubly-fed induction generators having wind turbines as prime movers and operating connected to a power network. The evaluation is intended to demonstrate that a PBC strategy initially designed to control generation at unity power factor can control power exchange at a fixed active power delivery to the grid with different power factors. The system model assumes a wind flow of constant kinetic energy and hence a constant mechanical torque in the turbine shaft. The power network is modeled as an infinite bus connected through a line-impedance to the generator terminals. The obtained results show that the PBC strategy is simple and effective and that the active and reactive power exchange with the power system can be adequately controlled.","PeriodicalId":119218,"journal":{"name":"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Passivity Based Control of Doubly-Fed Induction Generators in Wind Turbines\",\"authors\":\"I. López-García, V. M. Jimenez-Mondragon, E. Campero-Littlewood, G. Espinosa-Pérez\",\"doi\":\"10.1109/CERMA.2010.125\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the evaluation of a passivity based control (PBC) strategy for doubly-fed induction generators having wind turbines as prime movers and operating connected to a power network. The evaluation is intended to demonstrate that a PBC strategy initially designed to control generation at unity power factor can control power exchange at a fixed active power delivery to the grid with different power factors. The system model assumes a wind flow of constant kinetic energy and hence a constant mechanical torque in the turbine shaft. The power network is modeled as an infinite bus connected through a line-impedance to the generator terminals. The obtained results show that the PBC strategy is simple and effective and that the active and reactive power exchange with the power system can be adequately controlled.\",\"PeriodicalId\":119218,\"journal\":{\"name\":\"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CERMA.2010.125\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CERMA.2010.125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文研究了以风力发电机为原动机并网运行的双馈感应发电机的无源控制策略。该评估旨在证明PBC策略最初设计为在统一功率因数下控制发电,可以在不同功率因数的固定有功电力输送到电网时控制电力交换。该系统模型假设一个恒定动能的风流,因此在涡轮轴上有恒定的机械扭矩。电网被建模为通过线阻抗连接到发电机终端的无限母线。仿真结果表明,PBC策略简单有效,能充分控制与电力系统的有功和无功交换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Passivity Based Control of Doubly-Fed Induction Generators in Wind Turbines
This paper presents the evaluation of a passivity based control (PBC) strategy for doubly-fed induction generators having wind turbines as prime movers and operating connected to a power network. The evaluation is intended to demonstrate that a PBC strategy initially designed to control generation at unity power factor can control power exchange at a fixed active power delivery to the grid with different power factors. The system model assumes a wind flow of constant kinetic energy and hence a constant mechanical torque in the turbine shaft. The power network is modeled as an infinite bus connected through a line-impedance to the generator terminals. The obtained results show that the PBC strategy is simple and effective and that the active and reactive power exchange with the power system can be adequately controlled.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信