{"title":"ANALISIS STRUKTUR ATAS PASCA GEMPA BANGUNAN BERTINGKAT KANTOR WALI NAGARI MALAMPAH KABUPATEN PASAMAN","authors":"Fransisko Fransisko, Deddy Kurniawan, Elfania Bastian","doi":"10.33559/err.v2i1.1367","DOIUrl":null,"url":null,"abstract":"In general, the upper structure includes beams, columns, floor plates which function to support the loads acting on a building. Calculations that will be carried out on the construction of the Wali Nagari Malampah Office are floor slabs, beams and columns. Structural loads (dead loads, live loads) are based on SNI 03-2847:2002 and earthquake loads are based on SNI 03-1726:2019, where the portal is calculated and modeled using the SAP2000 program. The purpose of this calculation is to get an overview of the basic principles of planning and reviewing the building structure, comparing the results of the author's calculations with the results of the planning consultant's calculations. From the calculation results, the largest moment in beam B2 is 64.8586 kN-m and the largest moment in column K1 (40 x 40 cm) is 8.4235 kN-m. For floor slabs, there are differences in reinforcement, namely: floor slab thickness of 120 mm, reinforcement 10-150 mm for the x direction and y direction of the author, floor slab 120 mm, reinforcement 10- 250 mm for the x direction and y direction of the planner, column K1( 40 x 40 cm) 16 D 19 and column K2 (30 x 30 cm) 8 D 19 (same as the planner), For beams B1 and B2 there are differences in dimensions and reinforcement, namely: beam B1 (30 x 45 cm) 4 D 19 authors , block B1 (30 x 50 cm) 5 D 19 planner, for beam B2 (25 x 40 cm) 4 D 19 (same as planner).Keywords: Upper structure, Reinforcement, Sap 2000","PeriodicalId":273539,"journal":{"name":"Ensiklopedia Research and Community Service Review","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ensiklopedia Research and Community Service Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33559/err.v2i1.1367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
一般来说,上部结构包括梁、柱、楼板,它们的作用是支撑作用在建筑物上的荷载。将对Wali Nagari Malampah办公室的建造进行计算,包括楼板、梁和柱。结构荷载(恒载、活载)基于SNI 03-2847:2002,地震荷载基于SNI 03-1726:2019,其中门户使用SAP2000程序进行计算和建模。本次计算的目的是对建筑结构的规划和复核的基本原则进行概述,并将笔者的计算结果与规划顾问的计算结果进行比较。计算结果表明,B2梁的最大弯矩为64.8586 kN-m, K1柱(40 × 40 cm)的最大弯矩为8.4235 kN-m。楼板钢筋有差异,即:楼板厚度120毫米,强化10 - 150 mm x方向和y方向的作者,楼板120毫米,强化10 - 250 mm x方向和y方向的规划师,列K1 16 D 19(40 * 40厘米)和列K2 (30 x 30厘米)8 D 19(规划师一样),梁B1和B2存在差异的维度和强化,即:横梁B1 (30 × 45厘米)4d19作者,B1块(30 × 50厘米)5d19规划师,横梁B2 (25 × 40厘米)4d19(与规划师相同)。关键词:上部结构,加固,Sap 2000
ANALISIS STRUKTUR ATAS PASCA GEMPA BANGUNAN BERTINGKAT KANTOR WALI NAGARI MALAMPAH KABUPATEN PASAMAN
In general, the upper structure includes beams, columns, floor plates which function to support the loads acting on a building. Calculations that will be carried out on the construction of the Wali Nagari Malampah Office are floor slabs, beams and columns. Structural loads (dead loads, live loads) are based on SNI 03-2847:2002 and earthquake loads are based on SNI 03-1726:2019, where the portal is calculated and modeled using the SAP2000 program. The purpose of this calculation is to get an overview of the basic principles of planning and reviewing the building structure, comparing the results of the author's calculations with the results of the planning consultant's calculations. From the calculation results, the largest moment in beam B2 is 64.8586 kN-m and the largest moment in column K1 (40 x 40 cm) is 8.4235 kN-m. For floor slabs, there are differences in reinforcement, namely: floor slab thickness of 120 mm, reinforcement 10-150 mm for the x direction and y direction of the author, floor slab 120 mm, reinforcement 10- 250 mm for the x direction and y direction of the planner, column K1( 40 x 40 cm) 16 D 19 and column K2 (30 x 30 cm) 8 D 19 (same as the planner), For beams B1 and B2 there are differences in dimensions and reinforcement, namely: beam B1 (30 x 45 cm) 4 D 19 authors , block B1 (30 x 50 cm) 5 D 19 planner, for beam B2 (25 x 40 cm) 4 D 19 (same as planner).Keywords: Upper structure, Reinforcement, Sap 2000