电流调节三相电压源变换器的广义过调制方法

G. Dong, O. Ojo
{"title":"电流调节三相电压源变换器的广义过调制方法","authors":"G. Dong, O. Ojo","doi":"10.1109/IAS.2004.1348784","DOIUrl":null,"url":null,"abstract":"In most motor drive and utility applications, three-phase voltage source converters are required to operate in the over-modulation regions to improve steady-state capabilities and dynamic system performance and transit from the linear modulation region into the overmodulation and six-step modes seamlessly. This work presents a closed-loop current regulation concept for converter fed loads using the generalized space vector (GSVPWM) and generalized discontinuous carrier-based pulse-width modulation (GDPWM) schemes which operates effectively in the linear and overmodulation regions. The harmonic currents generated in these operational modes which naturally degrade the classical PI regulators are eliminated from the controller path by an open-loop harmonic current estimation scheme to ensure current regulation in the synchronous reference frame. The realization of the proposed modulation schemes and current regulation concept are validated by steady-state experimental results and dynamic response of a current regulated inverter feeding an impedance load.","PeriodicalId":131410,"journal":{"name":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A generalized over-modulation methodology for current regulated three-phase voltage source converters\",\"authors\":\"G. Dong, O. Ojo\",\"doi\":\"10.1109/IAS.2004.1348784\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In most motor drive and utility applications, three-phase voltage source converters are required to operate in the over-modulation regions to improve steady-state capabilities and dynamic system performance and transit from the linear modulation region into the overmodulation and six-step modes seamlessly. This work presents a closed-loop current regulation concept for converter fed loads using the generalized space vector (GSVPWM) and generalized discontinuous carrier-based pulse-width modulation (GDPWM) schemes which operates effectively in the linear and overmodulation regions. The harmonic currents generated in these operational modes which naturally degrade the classical PI regulators are eliminated from the controller path by an open-loop harmonic current estimation scheme to ensure current regulation in the synchronous reference frame. The realization of the proposed modulation schemes and current regulation concept are validated by steady-state experimental results and dynamic response of a current regulated inverter feeding an impedance load.\",\"PeriodicalId\":131410,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2004.1348784\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2004.1348784","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在大多数电机驱动和公用事业应用中,三相电压源变换器需要在过调制区域工作,以提高稳态能力和动态系统性能,并从线性调制区域无缝过渡到过调制和六步模式。本文提出了一种基于广义空间矢量(GSVPWM)和基于广义不连续载波的脉宽调制(GDPWM)方案的变换器负载闭环电流调节概念,该方案在线性和过调制区域有效工作。在这些工作模式下产生的谐波电流自然地降低了经典PI调节器,通过开环谐波电流估计方案从控制器路径中消除,以确保同步参考框架中的电流调节。稳态实验结果和电流调节逆变器馈入阻抗负载的动态响应验证了所提出的调制方案和电流调节概念的实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A generalized over-modulation methodology for current regulated three-phase voltage source converters
In most motor drive and utility applications, three-phase voltage source converters are required to operate in the over-modulation regions to improve steady-state capabilities and dynamic system performance and transit from the linear modulation region into the overmodulation and six-step modes seamlessly. This work presents a closed-loop current regulation concept for converter fed loads using the generalized space vector (GSVPWM) and generalized discontinuous carrier-based pulse-width modulation (GDPWM) schemes which operates effectively in the linear and overmodulation regions. The harmonic currents generated in these operational modes which naturally degrade the classical PI regulators are eliminated from the controller path by an open-loop harmonic current estimation scheme to ensure current regulation in the synchronous reference frame. The realization of the proposed modulation schemes and current regulation concept are validated by steady-state experimental results and dynamic response of a current regulated inverter feeding an impedance load.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信