G. V. Podporkin, E. Y. Enkin, E. S. Kalakutsky, V. Pilshikov, A. Sivaev
{"title":"220kv架空输电线路防雷用多室绝缘子避雷器的研制","authors":"G. V. Podporkin, E. Y. Enkin, E. S. Kalakutsky, V. Pilshikov, A. Sivaev","doi":"10.1109/SIPDA.2011.6088440","DOIUrl":null,"url":null,"abstract":"Reported are results of integrated research of electrical, mechanical and climatic characteristics of multi-chamber insulators-arresters (MCIA) and MCIA strings (MCIAS) for lightning protection of 220 kV overhead power lines without shielding wire.","PeriodicalId":277573,"journal":{"name":"2011 International Symposium on Lightning Protection","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Development of multi-chamber insulator-arresters for lightning protection of 220 kV overhead transmission lines\",\"authors\":\"G. V. Podporkin, E. Y. Enkin, E. S. Kalakutsky, V. Pilshikov, A. Sivaev\",\"doi\":\"10.1109/SIPDA.2011.6088440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reported are results of integrated research of electrical, mechanical and climatic characteristics of multi-chamber insulators-arresters (MCIA) and MCIA strings (MCIAS) for lightning protection of 220 kV overhead power lines without shielding wire.\",\"PeriodicalId\":277573,\"journal\":{\"name\":\"2011 International Symposium on Lightning Protection\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Symposium on Lightning Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2011.6088440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Symposium on Lightning Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2011.6088440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of multi-chamber insulator-arresters for lightning protection of 220 kV overhead transmission lines
Reported are results of integrated research of electrical, mechanical and climatic characteristics of multi-chamber insulators-arresters (MCIA) and MCIA strings (MCIAS) for lightning protection of 220 kV overhead power lines without shielding wire.