Pep-II探测器触发与数据采集系统设计

R. Becker-Szendy, D. Briggs, G. Haller, J. Hoeflich, W. Innes
{"title":"Pep-II探测器触发与数据采集系统设计","authors":"R. Becker-Szendy, D. Briggs, G. Haller, J. Hoeflich, W. Innes","doi":"10.1109/NSSMIC.1993.701766","DOIUrl":null,"url":null,"abstract":"This paper proposes a design of a trigger and data acquisition system for a detector at the PEP-II B Factory. The system is asynchronous, data-driven, and scalable. Design goals include orthogonal tracking and calorimetric triggers, minimal dead time, graceful degradation, high efficiency, and useful performance in the face of backgrounds so high as to overwhelm reconstruction. Also described are instrumentation of the Drift Chamber, based on 8-bit FADCs, and of the Calorimeter, based on a new custom integrated circuit, the Charge Amplifier with Range Encoding (CARE), and 10-bit ADCs. This design employs commercial embedded CPUs in VME and VXI crates. >","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design Of A Trigger And Data Acquisition System For A Detector At Pep-II\",\"authors\":\"R. Becker-Szendy, D. Briggs, G. Haller, J. Hoeflich, W. Innes\",\"doi\":\"10.1109/NSSMIC.1993.701766\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a design of a trigger and data acquisition system for a detector at the PEP-II B Factory. The system is asynchronous, data-driven, and scalable. Design goals include orthogonal tracking and calorimetric triggers, minimal dead time, graceful degradation, high efficiency, and useful performance in the face of backgrounds so high as to overwhelm reconstruction. Also described are instrumentation of the Drift Chamber, based on 8-bit FADCs, and of the Calorimeter, based on a new custom integrated circuit, the Charge Amplifier with Range Encoding (CARE), and 10-bit ADCs. This design employs commercial embedded CPUs in VME and VXI crates. >\",\"PeriodicalId\":287813,\"journal\":{\"name\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1993.701766\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.701766","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了一种用于PEP-II B工厂探测器的触发和数据采集系统的设计。该系统是异步的、数据驱动的和可扩展的。设计目标包括正交跟踪和量热触发,最小死区时间,优雅的退化,高效率,以及面对高到足以淹没重建的背景时的有用性能。还介绍了基于8位fadc的漂移室和基于新型定制集成电路的量热计的仪器,具有范围编码(CARE)的电荷放大器和10位adc。本设计在VME和VXI板条箱中采用商用嵌入式cpu。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design Of A Trigger And Data Acquisition System For A Detector At Pep-II
This paper proposes a design of a trigger and data acquisition system for a detector at the PEP-II B Factory. The system is asynchronous, data-driven, and scalable. Design goals include orthogonal tracking and calorimetric triggers, minimal dead time, graceful degradation, high efficiency, and useful performance in the face of backgrounds so high as to overwhelm reconstruction. Also described are instrumentation of the Drift Chamber, based on 8-bit FADCs, and of the Calorimeter, based on a new custom integrated circuit, the Charge Amplifier with Range Encoding (CARE), and 10-bit ADCs. This design employs commercial embedded CPUs in VME and VXI crates. >
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信