{"title":"【吲哚菁绿视频荧光血管造影定量图像分析参考值】。","authors":"C Prünte","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Indocyanine green video-fluorescence angiography was performed in 46 healthy normal subjects between the ages of 20 and 81 years using a 30 degrees Zeiss fundus camera, an external light supply and a high resolution CCD camera. Pictures were directly stored in a picture analysis system based on a PC with a temporal resolution of 25 pictures per second. Using statistical picture analysis, choroidal blood-flow parameters were obtained in a round area of interest with a diameter of 8 degrees with the center in the fovea. The parameters include: the mean arterial filling time (AFT) and the mean capillary density (MCD) in the choroid. There was no correlation for one of these parameters with arterial blood pressure or intraocular pressure. All values for the AFT were on an equal level for normal subjects younger than 65 years. Older normal subjects in some cases had clearly increased arterial filling times. The density of the capillary network in the choroid was significantly reduced with increasing age, and there was reduced density of the capillary network in normals with myopia.</p>","PeriodicalId":12437,"journal":{"name":"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","volume":"88 3","pages":"233-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Reference values for quantitative image analysis of indocyanine green video-fluorescence angiography].\",\"authors\":\"C Prünte\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Indocyanine green video-fluorescence angiography was performed in 46 healthy normal subjects between the ages of 20 and 81 years using a 30 degrees Zeiss fundus camera, an external light supply and a high resolution CCD camera. Pictures were directly stored in a picture analysis system based on a PC with a temporal resolution of 25 pictures per second. Using statistical picture analysis, choroidal blood-flow parameters were obtained in a round area of interest with a diameter of 8 degrees with the center in the fovea. The parameters include: the mean arterial filling time (AFT) and the mean capillary density (MCD) in the choroid. There was no correlation for one of these parameters with arterial blood pressure or intraocular pressure. All values for the AFT were on an equal level for normal subjects younger than 65 years. Older normal subjects in some cases had clearly increased arterial filling times. The density of the capillary network in the choroid was significantly reduced with increasing age, and there was reduced density of the capillary network in normals with myopia.</p>\",\"PeriodicalId\":12437,\"journal\":{\"name\":\"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft\",\"volume\":\"88 3\",\"pages\":\"233-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用30度蔡司眼底相机、外置光源和高分辨率CCD相机对46例20 ~ 81岁的健康正常人进行了吲哚菁绿视频荧光血管造影。图像直接存储在基于PC的图像分析系统中,时间分辨率为每秒25张。采用统计图像分析,获得以中央凹为中心直径为8度的圆形感兴趣区域的脉络膜血流参数。参数包括:平均动脉充盈时间(AFT)和脉络膜平均毛细血管密度(MCD)。这些参数与动脉血压或眼压没有相关性。在年龄小于65岁的正常受试者中,所有的AFT值都处于相同的水平。在某些情况下,年长的正常受试者动脉充盈时间明显增加。随着年龄的增长,脉络膜毛细血管网的密度明显降低,正常近视患者的毛细血管网密度也明显降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Reference values for quantitative image analysis of indocyanine green video-fluorescence angiography].

Indocyanine green video-fluorescence angiography was performed in 46 healthy normal subjects between the ages of 20 and 81 years using a 30 degrees Zeiss fundus camera, an external light supply and a high resolution CCD camera. Pictures were directly stored in a picture analysis system based on a PC with a temporal resolution of 25 pictures per second. Using statistical picture analysis, choroidal blood-flow parameters were obtained in a round area of interest with a diameter of 8 degrees with the center in the fovea. The parameters include: the mean arterial filling time (AFT) and the mean capillary density (MCD) in the choroid. There was no correlation for one of these parameters with arterial blood pressure or intraocular pressure. All values for the AFT were on an equal level for normal subjects younger than 65 years. Older normal subjects in some cases had clearly increased arterial filling times. The density of the capillary network in the choroid was significantly reduced with increasing age, and there was reduced density of the capillary network in normals with myopia.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信