海上风电和常规发电中断对交直流输电系统动态性能的影响

M. Ndreko, M. Popov, J. Rueda-Torres, M. V. D. van der Meijden
{"title":"海上风电和常规发电中断对交直流输电系统动态性能的影响","authors":"M. Ndreko, M. Popov, J. Rueda-Torres, M. V. D. van der Meijden","doi":"10.1109/PTC.2015.7232397","DOIUrl":null,"url":null,"abstract":"The impact of offshore wind power and conventional generation outages on the dynamic performance of multi terminal DC interfaced AC systems is ascertained in this paper. In addition, the paper addresses the share of primary frequency reserves as well as synthetic inertia response between MTDC connected AC systems focusing on the interactions between the direct voltage control loop and the dedicated primary and synthetic inertia response control loops. The classical single machine modeling approach is used for the AC systems extended by common dynamic models of MTDC grids in a so called simple AC-DC model adequate for frequency stability studies. The results of this paper can be used as reference for grid code design and optimization of MTDC grid control loops operating next to AC power systems.","PeriodicalId":193448,"journal":{"name":"2015 IEEE Eindhoven PowerTech","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Impact of offshore wind and conventional generation outages on the dynamic performance of AC-DC transmission systems\",\"authors\":\"M. Ndreko, M. Popov, J. Rueda-Torres, M. V. D. van der Meijden\",\"doi\":\"10.1109/PTC.2015.7232397\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The impact of offshore wind power and conventional generation outages on the dynamic performance of multi terminal DC interfaced AC systems is ascertained in this paper. In addition, the paper addresses the share of primary frequency reserves as well as synthetic inertia response between MTDC connected AC systems focusing on the interactions between the direct voltage control loop and the dedicated primary and synthetic inertia response control loops. The classical single machine modeling approach is used for the AC systems extended by common dynamic models of MTDC grids in a so called simple AC-DC model adequate for frequency stability studies. The results of this paper can be used as reference for grid code design and optimization of MTDC grid control loops operating next to AC power systems.\",\"PeriodicalId\":193448,\"journal\":{\"name\":\"2015 IEEE Eindhoven PowerTech\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Eindhoven PowerTech\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PTC.2015.7232397\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Eindhoven PowerTech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PTC.2015.7232397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文确定了海上风电和常规发电中断对多端直流接口交流系统动态性能的影响。此外,本文还讨论了MTDC连接交流系统之间的一次频率储备份额和综合惯性响应,重点是直接电压控制回路与专用的一次和综合惯性响应控制回路之间的相互作用。本文采用经典的单机建模方法,将MTDC电网的常用动态模型扩展为适合于频率稳定性研究的简单交直流模型。本文的研究结果可为毗邻交流电力系统运行的MTDC电网控制回路的电网规范设计和优化提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of offshore wind and conventional generation outages on the dynamic performance of AC-DC transmission systems
The impact of offshore wind power and conventional generation outages on the dynamic performance of multi terminal DC interfaced AC systems is ascertained in this paper. In addition, the paper addresses the share of primary frequency reserves as well as synthetic inertia response between MTDC connected AC systems focusing on the interactions between the direct voltage control loop and the dedicated primary and synthetic inertia response control loops. The classical single machine modeling approach is used for the AC systems extended by common dynamic models of MTDC grids in a so called simple AC-DC model adequate for frequency stability studies. The results of this paper can be used as reference for grid code design and optimization of MTDC grid control loops operating next to AC power systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信