A. Márquez, A. Sánchez-Montes, J. Francés, D. Puerto, E. Calzado, S. Gallego, I. Pascual, A. Beléndez
{"title":"基于蒙特卡罗的液晶器件偏振定标分析","authors":"A. Márquez, A. Sánchez-Montes, J. Francés, D. Puerto, E. Calzado, S. Gallego, I. Pascual, A. Beléndez","doi":"10.1364/3d.2022.3tu5a.7","DOIUrl":null,"url":null,"abstract":"An advanced polarimetric model for liquid crystal devices is presented and the sources of uncertainty to determine the values of its parameters are evaluated using a Monte-Carlo approach.","PeriodicalId":286361,"journal":{"name":"Imaging and Applied Optics Congress 2022 (3D, AOA, COSI, ISA, pcAOP)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monte-Carlo based analysis of polarimetric calibration of liquid crystal devices\",\"authors\":\"A. Márquez, A. Sánchez-Montes, J. Francés, D. Puerto, E. Calzado, S. Gallego, I. Pascual, A. Beléndez\",\"doi\":\"10.1364/3d.2022.3tu5a.7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An advanced polarimetric model for liquid crystal devices is presented and the sources of uncertainty to determine the values of its parameters are evaluated using a Monte-Carlo approach.\",\"PeriodicalId\":286361,\"journal\":{\"name\":\"Imaging and Applied Optics Congress 2022 (3D, AOA, COSI, ISA, pcAOP)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging and Applied Optics Congress 2022 (3D, AOA, COSI, ISA, pcAOP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1364/3d.2022.3tu5a.7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging and Applied Optics Congress 2022 (3D, AOA, COSI, ISA, pcAOP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/3d.2022.3tu5a.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Monte-Carlo based analysis of polarimetric calibration of liquid crystal devices
An advanced polarimetric model for liquid crystal devices is presented and the sources of uncertainty to determine the values of its parameters are evaluated using a Monte-Carlo approach.