被溢出的纸浆覆盖或部分淹没的TEFC感应电动机的热降额

M. Valenzuela, M. Millar, J. Tapia, J. Rooks
{"title":"被溢出的纸浆覆盖或部分淹没的TEFC感应电动机的热降额","authors":"M. Valenzuela, M. Millar, J. Tapia, J. Rooks","doi":"10.1109/PAPCON.2004.1338356","DOIUrl":null,"url":null,"abstract":"Induction motors driving the agitators in pulp tanks are affected by the leakage of pulp that coats their inter-fin channels, blocks the air inlets of the fan cover, or partially floods them. This paper presents a complete thermal evaluation of TEFC induction motors during these abnormal conditions. A totally enclosed fan cooled (TEFC) induction motor fitted with 12 thermocouples was tested in the different situations of interest, including pulp spilled over the frame, in the air intake, and partially flooding it. Winding, frame, and bearing temperatures were measured. These results are used to determine the required oversizing of an agitator motor in order to assure that the motor will not fail even if the inter-fin channels become obstructed with spilled pulp.","PeriodicalId":189773,"journal":{"name":"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)","volume":"109 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Thermal derating of TEFC induction motors coated or partially flooded by spilled pulp\",\"authors\":\"M. Valenzuela, M. Millar, J. Tapia, J. Rooks\",\"doi\":\"10.1109/PAPCON.2004.1338356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Induction motors driving the agitators in pulp tanks are affected by the leakage of pulp that coats their inter-fin channels, blocks the air inlets of the fan cover, or partially floods them. This paper presents a complete thermal evaluation of TEFC induction motors during these abnormal conditions. A totally enclosed fan cooled (TEFC) induction motor fitted with 12 thermocouples was tested in the different situations of interest, including pulp spilled over the frame, in the air intake, and partially flooding it. Winding, frame, and bearing temperatures were measured. These results are used to determine the required oversizing of an agitator motor in order to assure that the motor will not fail even if the inter-fin channels become obstructed with spilled pulp.\",\"PeriodicalId\":189773,\"journal\":{\"name\":\"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)\",\"volume\":\"109 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAPCON.2004.1338356\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.2004.1338356","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

驱动纸浆槽内搅拌器的感应电动机受到纸浆泄漏的影响,纸浆泄漏覆盖了它们的翅片间通道,阻塞了风扇盖的进气口,或部分淹没了它们。本文给出了TEFC感应电动机在这些异常条件下的完整热评估。一个装有12个热电偶的全封闭风扇冷却(TEFC)感应电机在不同的情况下进行了测试,包括纸浆溢出框架,进气口和部分淹没它。测量了绕组、机架和轴承的温度。这些结果用于确定搅拌器电机所需的超大尺寸,以确保即使桨片间通道被溢出的纸浆阻塞,电机也不会失效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal derating of TEFC induction motors coated or partially flooded by spilled pulp
Induction motors driving the agitators in pulp tanks are affected by the leakage of pulp that coats their inter-fin channels, blocks the air inlets of the fan cover, or partially floods them. This paper presents a complete thermal evaluation of TEFC induction motors during these abnormal conditions. A totally enclosed fan cooled (TEFC) induction motor fitted with 12 thermocouples was tested in the different situations of interest, including pulp spilled over the frame, in the air intake, and partially flooding it. Winding, frame, and bearing temperatures were measured. These results are used to determine the required oversizing of an agitator motor in order to assure that the motor will not fail even if the inter-fin channels become obstructed with spilled pulp.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信