{"title":"半导体制造过程中晶圆槽相关放气缺陷的控制","authors":"J. Jeong, Jinwoo Park, Eunyoung Han, Jaungjoo Kim, Hong Kim","doi":"10.1109/ASMC.2019.8791794","DOIUrl":null,"url":null,"abstract":"In this paper, a study on a behavior of waiting-time related defect which strongly depends on a wafer slot position in FOUP (Front Opening Unified Pod) was carried out. The occurrence of the waiting-time dependent defects in the processing tools was found to be affected by the flow pattern, moisture and process outgassing distribution in equipment EFEM (Equipment Front End Module) and FOUP. In order to control this problem, which also causes to deteriorate the production yield, it is essential to establish a system that is capable of monitoring the wafer-level waiting- time of each wafer in the processing tools. Optimizing the flow pattern of air which contains humidity and process outgassing or AMC (Airborne Molecular Contaminants), and N2 purge gas in EFEM and FOUP is required as well. Various types of load-port N2 gas purging system inside EFEM and FOUP were reviewed using CFD (Computational Fluid Dynamics) simulations and a fully charged N2 circulating EFEM exhibited the best defect control performance.","PeriodicalId":287541,"journal":{"name":"2019 30th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Control of Wafer Slot-Dependent Outgassing Defects during Semiconductor Manufacture Processes\",\"authors\":\"J. Jeong, Jinwoo Park, Eunyoung Han, Jaungjoo Kim, Hong Kim\",\"doi\":\"10.1109/ASMC.2019.8791794\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a study on a behavior of waiting-time related defect which strongly depends on a wafer slot position in FOUP (Front Opening Unified Pod) was carried out. The occurrence of the waiting-time dependent defects in the processing tools was found to be affected by the flow pattern, moisture and process outgassing distribution in equipment EFEM (Equipment Front End Module) and FOUP. In order to control this problem, which also causes to deteriorate the production yield, it is essential to establish a system that is capable of monitoring the wafer-level waiting- time of each wafer in the processing tools. Optimizing the flow pattern of air which contains humidity and process outgassing or AMC (Airborne Molecular Contaminants), and N2 purge gas in EFEM and FOUP is required as well. Various types of load-port N2 gas purging system inside EFEM and FOUP were reviewed using CFD (Computational Fluid Dynamics) simulations and a fully charged N2 circulating EFEM exhibited the best defect control performance.\",\"PeriodicalId\":287541,\"journal\":{\"name\":\"2019 30th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 30th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASMC.2019.8791794\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 30th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASMC.2019.8791794","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文研究了前开口统一吊舱中与晶圆槽位置密切相关的等待时间缺陷的行为。发现加工工具中等待时间相关缺陷的发生受设备EFEM(设备前端模块)和FOUP中的流态、水分和过程放气分布的影响。为了控制这一问题,也会导致生产良率下降,建立一个能够监控每个晶圆在加工工具中等待时间的系统是至关重要的。在EFEM和FOUP中,还需要优化含有湿度和过程放气或AMC (Airborne Molecular Contaminants)以及N2吹扫气体的气流模式。利用CFD (Computational Fluid Dynamics)模拟分析了不同类型的负载口氮气吹扫系统在EFEM和FOUP内的缺陷控制性能,结果表明充满氮气循环的EFEM具有最佳的缺陷控制性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Control of Wafer Slot-Dependent Outgassing Defects during Semiconductor Manufacture Processes
In this paper, a study on a behavior of waiting-time related defect which strongly depends on a wafer slot position in FOUP (Front Opening Unified Pod) was carried out. The occurrence of the waiting-time dependent defects in the processing tools was found to be affected by the flow pattern, moisture and process outgassing distribution in equipment EFEM (Equipment Front End Module) and FOUP. In order to control this problem, which also causes to deteriorate the production yield, it is essential to establish a system that is capable of monitoring the wafer-level waiting- time of each wafer in the processing tools. Optimizing the flow pattern of air which contains humidity and process outgassing or AMC (Airborne Molecular Contaminants), and N2 purge gas in EFEM and FOUP is required as well. Various types of load-port N2 gas purging system inside EFEM and FOUP were reviewed using CFD (Computational Fluid Dynamics) simulations and a fully charged N2 circulating EFEM exhibited the best defect control performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信