{"title":"靠近大导电区域的空气终端系统的分离距离","authors":"W. Zischank, K. Stimper","doi":"10.1109/ICLP.2012.6344408","DOIUrl":null,"url":null,"abstract":"In case of a direct lightning strike to a building dangerous sparking may occur between the external lightning protection system and conductive parts inside or at the building. To avoid such side flashes a minimum separation distance between these parts has to be kept. The standard IEC 62305-3 provides an equation and parameters to determine the necessary separation distance. The parameters given there were developed for large loops, many meters wide. Nowadays, it often occurs that the air termination system is to be placed relatively close to large conductive areas. Typical examples are air termination wires placed on a metal roof or on a reinforced concrete structure. For such cases, it has to be expected that the parameters are different to those given in IEC 62305-3. Objective of this paper is to experimentally determine these parameters.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Separation distances for air termination systems in proximity to large conductive areas\",\"authors\":\"W. Zischank, K. Stimper\",\"doi\":\"10.1109/ICLP.2012.6344408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In case of a direct lightning strike to a building dangerous sparking may occur between the external lightning protection system and conductive parts inside or at the building. To avoid such side flashes a minimum separation distance between these parts has to be kept. The standard IEC 62305-3 provides an equation and parameters to determine the necessary separation distance. The parameters given there were developed for large loops, many meters wide. Nowadays, it often occurs that the air termination system is to be placed relatively close to large conductive areas. Typical examples are air termination wires placed on a metal roof or on a reinforced concrete structure. For such cases, it has to be expected that the parameters are different to those given in IEC 62305-3. Objective of this paper is to experimentally determine these parameters.\",\"PeriodicalId\":400743,\"journal\":{\"name\":\"2012 International Conference on Lightning Protection (ICLP)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2012.6344408\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

当建筑物遭受直接雷击时,外部防雷系统与建筑物内部或建筑物上的导电部件之间可能产生危险的火花。为了避免这种侧面闪光,这些部件之间必须保持最小的分离距离。标准IEC 62305-3提供了一个公式和参数来确定必要的分离距离。这里给出的参数是为许多米宽的大回路设计的。如今,空气终端系统经常被放置在相对靠近大导电性区域的地方。典型的例子是放置在金属屋顶或钢筋混凝土结构上的空气终止线。对于这种情况,必须期望参数与IEC 62305-3中给出的参数不同。本文的目的是通过实验确定这些参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Separation distances for air termination systems in proximity to large conductive areas
In case of a direct lightning strike to a building dangerous sparking may occur between the external lightning protection system and conductive parts inside or at the building. To avoid such side flashes a minimum separation distance between these parts has to be kept. The standard IEC 62305-3 provides an equation and parameters to determine the necessary separation distance. The parameters given there were developed for large loops, many meters wide. Nowadays, it often occurs that the air termination system is to be placed relatively close to large conductive areas. Typical examples are air termination wires placed on a metal roof or on a reinforced concrete structure. For such cases, it has to be expected that the parameters are different to those given in IEC 62305-3. Objective of this paper is to experimentally determine these parameters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信