7.5兆赫儿童相控阵经食管内窥镜

J. Piel, R. Lewandowski, P. Lorraine, L. Smith, T. Shiota, D. Sahn
{"title":"7.5兆赫儿童相控阵经食管内窥镜","authors":"J. Piel, R. Lewandowski, P. Lorraine, L. Smith, T. Shiota, D. Sahn","doi":"10.1109/ULTSYM.1994.401881","DOIUrl":null,"url":null,"abstract":"This work extends the clinical benefits of phased array transesophageal echocardiography (TEE) with high detail and contrast resolution to include neonatal patients. We have built several prototype 64 element, 7.5 MHz phased array transducers housed in 6.2 mm endoscope shafts for use with commercially available imaging systems. The acoustic design is standard, but the miniaturized packaging of the electrical connections was quite challenging. The endoscopes demonstrate very good structural resolution and excellent sensitivity for color flow imaging and CW Doppler. They have been used on patients as small as 1.9 kg, frequently as an anatomical guide during catheter based interventions and during congenital-heart surgery. Array test data and representative clinical studies are shown","PeriodicalId":394363,"journal":{"name":"1994 Proceedings of IEEE Ultrasonics Symposium","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"7.5 MHz pediatric phased-array transesophageal endoscope\",\"authors\":\"J. Piel, R. Lewandowski, P. Lorraine, L. Smith, T. Shiota, D. Sahn\",\"doi\":\"10.1109/ULTSYM.1994.401881\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work extends the clinical benefits of phased array transesophageal echocardiography (TEE) with high detail and contrast resolution to include neonatal patients. We have built several prototype 64 element, 7.5 MHz phased array transducers housed in 6.2 mm endoscope shafts for use with commercially available imaging systems. The acoustic design is standard, but the miniaturized packaging of the electrical connections was quite challenging. The endoscopes demonstrate very good structural resolution and excellent sensitivity for color flow imaging and CW Doppler. They have been used on patients as small as 1.9 kg, frequently as an anatomical guide during catheter based interventions and during congenital-heart surgery. Array test data and representative clinical studies are shown\",\"PeriodicalId\":394363,\"journal\":{\"name\":\"1994 Proceedings of IEEE Ultrasonics Symposium\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1994 Proceedings of IEEE Ultrasonics Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1994.401881\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1994 Proceedings of IEEE Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1994.401881","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

这项工作扩展了高细节和对比度分辨率的相控阵经食管超声心动图(TEE)的临床益处,包括新生儿患者。我们已经建造了几个原型64元件,7.5 MHz相控阵换能器,安装在6.2毫米内窥镜轴中,用于商用成像系统。声学设计是标准的,但电气连接的小型化包装是相当具有挑战性的。该内窥镜在彩色血流成像和连续波多普勒成像方面具有良好的结构分辨率和灵敏度。它们已用于小至1.9公斤的患者,在导管干预和先天性心脏手术中经常用作解剖指南。阵列测试数据和有代表性的临床研究显示
本文章由计算机程序翻译,如有差异,请以英文原文为准。
7.5 MHz pediatric phased-array transesophageal endoscope
This work extends the clinical benefits of phased array transesophageal echocardiography (TEE) with high detail and contrast resolution to include neonatal patients. We have built several prototype 64 element, 7.5 MHz phased array transducers housed in 6.2 mm endoscope shafts for use with commercially available imaging systems. The acoustic design is standard, but the miniaturized packaging of the electrical connections was quite challenging. The endoscopes demonstrate very good structural resolution and excellent sensitivity for color flow imaging and CW Doppler. They have been used on patients as small as 1.9 kg, frequently as an anatomical guide during catheter based interventions and during congenital-heart surgery. Array test data and representative clinical studies are shown
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信