基于转矩-时间特性的感应发电机暂态稳定性分析

T. Senjyu, N. Sueyoshi, K. Uezato, H. Fujita, T. Funabashi
{"title":"基于转矩-时间特性的感应发电机暂态稳定性分析","authors":"T. Senjyu, N. Sueyoshi, K. Uezato, H. Fujita, T. Funabashi","doi":"10.1109/PEDS.2003.1282996","DOIUrl":null,"url":null,"abstract":"Transient stability assessment of wind power generator is one of main issues in power system security and operation. The transient stability for the wind power generator is determined by its corresponding critical clearing time (CCT). Conventionally, determination of the induction generator CCT involves a large number of trial and error methods that requires repetitive runs of related time domain simulation. In this paper, we present transient stability analysis technique for induction generator used in wind power generating system at three-phase fault conditions. The proposed method saves time in consuming the repetitive runs of related time domain simulation. The validity of the developed technique is confirmed by the results obtained from trial and error method using Matlab/Simulink.","PeriodicalId":106054,"journal":{"name":"The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003.","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Transient stability analysis of induction generator using torque-time characteristic\",\"authors\":\"T. Senjyu, N. Sueyoshi, K. Uezato, H. Fujita, T. Funabashi\",\"doi\":\"10.1109/PEDS.2003.1282996\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient stability assessment of wind power generator is one of main issues in power system security and operation. The transient stability for the wind power generator is determined by its corresponding critical clearing time (CCT). Conventionally, determination of the induction generator CCT involves a large number of trial and error methods that requires repetitive runs of related time domain simulation. In this paper, we present transient stability analysis technique for induction generator used in wind power generating system at three-phase fault conditions. The proposed method saves time in consuming the repetitive runs of related time domain simulation. The validity of the developed technique is confirmed by the results obtained from trial and error method using Matlab/Simulink.\",\"PeriodicalId\":106054,\"journal\":{\"name\":\"The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003.\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-11-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.2003.1282996\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2003.1282996","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

风电机组暂态稳定评估是电力系统安全运行的主要问题之一。风力发电机组的暂态稳定取决于其相应的临界清净时间(CCT)。通常,感应发电机CCT的确定涉及大量的试错方法,需要重复运行相关的时域仿真。本文提出了风电系统三相故障条件下感应发电机暂态稳定性分析技术。该方法节省了相关时域仿真的重复运行时间。通过Matlab/Simulink的试错法验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient stability analysis of induction generator using torque-time characteristic
Transient stability assessment of wind power generator is one of main issues in power system security and operation. The transient stability for the wind power generator is determined by its corresponding critical clearing time (CCT). Conventionally, determination of the induction generator CCT involves a large number of trial and error methods that requires repetitive runs of related time domain simulation. In this paper, we present transient stability analysis technique for induction generator used in wind power generating system at three-phase fault conditions. The proposed method saves time in consuming the repetitive runs of related time domain simulation. The validity of the developed technique is confirmed by the results obtained from trial and error method using Matlab/Simulink.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信