地理信息系统外各种PD传感器的灵敏度和抗噪声性能

T. Mizojiri, H. Murase, Y. Sawa, S. Maruyama, T. Nakajima, T. Hoshino
{"title":"地理信息系统外各种PD传感器的灵敏度和抗噪声性能","authors":"T. Mizojiri, H. Murase, Y. Sawa, S. Maruyama, T. Nakajima, T. Hoshino","doi":"10.1109/ISEIM.2008.4664532","DOIUrl":null,"url":null,"abstract":"This paper deals with the method of PD detection with the sensor (antenna) put at the outside of the GIS tank. It pays attention to the flange of the spacer as a leakage place of the PD electromagnetic radiation. Three kinds of antennas are proposed and made for trial purposes. And comparative study of the three antennas with the internal PD sensor (disc coupler) used worldwide so far is made from the viewpoint of the sensitivity characteristic and the noise-resistant performance. As a result, it is concluded that one kind of antenna has equal or even higher sensitivity to/than the internal disc coupler, without remarkable inferiority about the noise-resistant performance in the frequency range from 1.2 GHz to 2.7 GHz.","PeriodicalId":158811,"journal":{"name":"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)","volume":"112 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Sensitivities and noise-resistant performances of various PD sensors located outside a GIS\",\"authors\":\"T. Mizojiri, H. Murase, Y. Sawa, S. Maruyama, T. Nakajima, T. Hoshino\",\"doi\":\"10.1109/ISEIM.2008.4664532\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the method of PD detection with the sensor (antenna) put at the outside of the GIS tank. It pays attention to the flange of the spacer as a leakage place of the PD electromagnetic radiation. Three kinds of antennas are proposed and made for trial purposes. And comparative study of the three antennas with the internal PD sensor (disc coupler) used worldwide so far is made from the viewpoint of the sensitivity characteristic and the noise-resistant performance. As a result, it is concluded that one kind of antenna has equal or even higher sensitivity to/than the internal disc coupler, without remarkable inferiority about the noise-resistant performance in the frequency range from 1.2 GHz to 2.7 GHz.\",\"PeriodicalId\":158811,\"journal\":{\"name\":\"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)\",\"volume\":\"112 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEIM.2008.4664532\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEIM.2008.4664532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文研究了将传感器(天线)置于GIS储罐外部的PD检测方法。注意间隔片法兰作为PD电磁辐射的泄漏处。提出并制作了三种用于试验目的的天线。并从灵敏度特性和抗噪声性能两方面对三种天线与目前国际上使用的内置PD传感器(碟形耦合器)进行了比较研究。结果表明,在1.2 GHz ~ 2.7 GHz频率范围内,一种天线对内盘耦合器的灵敏度等于甚至高于内盘耦合器,抗噪声性能没有明显的不足。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sensitivities and noise-resistant performances of various PD sensors located outside a GIS
This paper deals with the method of PD detection with the sensor (antenna) put at the outside of the GIS tank. It pays attention to the flange of the spacer as a leakage place of the PD electromagnetic radiation. Three kinds of antennas are proposed and made for trial purposes. And comparative study of the three antennas with the internal PD sensor (disc coupler) used worldwide so far is made from the viewpoint of the sensitivity characteristic and the noise-resistant performance. As a result, it is concluded that one kind of antenna has equal or even higher sensitivity to/than the internal disc coupler, without remarkable inferiority about the noise-resistant performance in the frequency range from 1.2 GHz to 2.7 GHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信