纳秒脉冲电晕放电辐射

R. Baksht, Y. Yankelevich, A. Pokryvailo
{"title":"纳秒脉冲电晕放电辐射","authors":"R. Baksht, Y. Yankelevich, A. Pokryvailo","doi":"10.1109/PPC.2005.300474","DOIUrl":null,"url":null,"abstract":"Pulsed corona (PC) offers a real promise for degradation of pollutants in gas and water streams. Understanding of discharge physic is necessary for developing corona applications. This paper presents a study of pulse repetition frequency (PRF) effect on PC parameters: current, impedance and radiation. The study was carried out in a wire-to-wire geometry. A corona device with a central high-voltage electrode and two symmetrical grounded electrodes was used for model experiments. A nanosecond solid state power supply SM- 2N (100 kV, 5 ns, up to 300 Hz) was used for driving PC. We carried out also spectrum measurements by a SPEX monochromator. We registered the N2 second positive system and N2 + first negative system as a function of the discharge voltage and PRF.","PeriodicalId":200159,"journal":{"name":"2005 IEEE Pulsed Power Conference","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nanosecond Pulsed Corona Discharge Radiation\",\"authors\":\"R. Baksht, Y. Yankelevich, A. Pokryvailo\",\"doi\":\"10.1109/PPC.2005.300474\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pulsed corona (PC) offers a real promise for degradation of pollutants in gas and water streams. Understanding of discharge physic is necessary for developing corona applications. This paper presents a study of pulse repetition frequency (PRF) effect on PC parameters: current, impedance and radiation. The study was carried out in a wire-to-wire geometry. A corona device with a central high-voltage electrode and two symmetrical grounded electrodes was used for model experiments. A nanosecond solid state power supply SM- 2N (100 kV, 5 ns, up to 300 Hz) was used for driving PC. We carried out also spectrum measurements by a SPEX monochromator. We registered the N2 second positive system and N2 + first negative system as a function of the discharge voltage and PRF.\",\"PeriodicalId\":200159,\"journal\":{\"name\":\"2005 IEEE Pulsed Power Conference\",\"volume\":\"61 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 IEEE Pulsed Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.2005.300474\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2005.300474","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

脉冲电晕(PC)为气体和水流中的污染物降解提供了一个真正的希望。了解放电物理是开发电晕应用的必要条件。本文研究了脉冲重复频率(PRF)对PC机电流、阻抗和辐射参数的影响。这项研究是在导线对导线的几何结构中进行的。采用一个中心高压电极和两个对称接地电极的电晕装置进行模型实验。采用纳秒级固态电源SM- 2N (100 kV, 5 ns,高达300 Hz)驱动PC。我们还用SPEX单色仪进行了光谱测量。我们记录了N2第二正极系统和N2 +第一负极系统作为放电电压和PRF的函数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Nanosecond Pulsed Corona Discharge Radiation
Pulsed corona (PC) offers a real promise for degradation of pollutants in gas and water streams. Understanding of discharge physic is necessary for developing corona applications. This paper presents a study of pulse repetition frequency (PRF) effect on PC parameters: current, impedance and radiation. The study was carried out in a wire-to-wire geometry. A corona device with a central high-voltage electrode and two symmetrical grounded electrodes was used for model experiments. A nanosecond solid state power supply SM- 2N (100 kV, 5 ns, up to 300 Hz) was used for driving PC. We carried out also spectrum measurements by a SPEX monochromator. We registered the N2 second positive system and N2 + first negative system as a function of the discharge voltage and PRF.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信