{"title":"Dyna锁定转子(DLT)钉治疗股骨转子间骨折","authors":"Yong Sik Kim, J. Yoon, S. Han","doi":"10.5371/JKHS.2010.22.3.216","DOIUrl":null,"url":null,"abstract":"Purpose: We analyzed the clinical and radiological results after treatment of intertrochanteric fracture of the femur using a Dyna locking trochanteric (DLT) nail. Materials and Methods: From March 2008 to February 2009, 36 patients (10 males and 26 females) who had at least 6 months follow-up among 43 patients were included in our study. The average age of the patients was 76.4 years (range: 65~90 years) and the average follow-up period was 13.4 months (range: 9~21 months). We evaluated the radiological results such as the neck-shaft angle and the sliding length of the lag screw at last follow-up and the clinical results such as intraoperative complications, the operation time, the postoperative blood loss and the incidence of fixation failure. Results: The average neck-shaft angle at last follow-up was 131.1 degrees and the average sliding length of lag screw was 3.6 mm. Two cases (5.6%) of femoral shaft fracture during the insertion of a lag screw or nail happened and one case of stress fracture of the femoral neck occurred. Two cases of fixation failure developed due to deep infection or varus angulation. Conclusion: Fixation using a DLT nail can be a good option for the treatment of intertrochanteric fractures of the femur.","PeriodicalId":410202,"journal":{"name":"The Journal of the Korean Hip Society","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Treatment of Intertrochanteric Fracture of the Femur Using a Dyna Locking Trochanteric (DLT) Nail\",\"authors\":\"Yong Sik Kim, J. Yoon, S. Han\",\"doi\":\"10.5371/JKHS.2010.22.3.216\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: We analyzed the clinical and radiological results after treatment of intertrochanteric fracture of the femur using a Dyna locking trochanteric (DLT) nail. Materials and Methods: From March 2008 to February 2009, 36 patients (10 males and 26 females) who had at least 6 months follow-up among 43 patients were included in our study. The average age of the patients was 76.4 years (range: 65~90 years) and the average follow-up period was 13.4 months (range: 9~21 months). We evaluated the radiological results such as the neck-shaft angle and the sliding length of the lag screw at last follow-up and the clinical results such as intraoperative complications, the operation time, the postoperative blood loss and the incidence of fixation failure. Results: The average neck-shaft angle at last follow-up was 131.1 degrees and the average sliding length of lag screw was 3.6 mm. Two cases (5.6%) of femoral shaft fracture during the insertion of a lag screw or nail happened and one case of stress fracture of the femoral neck occurred. Two cases of fixation failure developed due to deep infection or varus angulation. Conclusion: Fixation using a DLT nail can be a good option for the treatment of intertrochanteric fractures of the femur.\",\"PeriodicalId\":410202,\"journal\":{\"name\":\"The Journal of the Korean Hip Society\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of the Korean Hip Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5371/JKHS.2010.22.3.216\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Korean Hip Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5371/JKHS.2010.22.3.216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Treatment of Intertrochanteric Fracture of the Femur Using a Dyna Locking Trochanteric (DLT) Nail
Purpose: We analyzed the clinical and radiological results after treatment of intertrochanteric fracture of the femur using a Dyna locking trochanteric (DLT) nail. Materials and Methods: From March 2008 to February 2009, 36 patients (10 males and 26 females) who had at least 6 months follow-up among 43 patients were included in our study. The average age of the patients was 76.4 years (range: 65~90 years) and the average follow-up period was 13.4 months (range: 9~21 months). We evaluated the radiological results such as the neck-shaft angle and the sliding length of the lag screw at last follow-up and the clinical results such as intraoperative complications, the operation time, the postoperative blood loss and the incidence of fixation failure. Results: The average neck-shaft angle at last follow-up was 131.1 degrees and the average sliding length of lag screw was 3.6 mm. Two cases (5.6%) of femoral shaft fracture during the insertion of a lag screw or nail happened and one case of stress fracture of the femoral neck occurred. Two cases of fixation failure developed due to deep infection or varus angulation. Conclusion: Fixation using a DLT nail can be a good option for the treatment of intertrochanteric fractures of the femur.