频谱减法技术参数的评价及其对语音信号质量的影响

H. Carvajal, N. García
{"title":"频谱减法技术参数的评价及其对语音信号质量的影响","authors":"H. Carvajal, N. García","doi":"10.1109/STSIVA.2013.6644918","DOIUrl":null,"url":null,"abstract":"This article presents the results of tests conducted to evaluate various versions of the spectral subtraction technique. Brief descriptions of the versions of the techniques evaluated and the measures used to evaluate them are given. The tests were conducted using a set of signals, containing voices of male speakers, that were contaminated with white gaussian noise at different levels of contamination. A relation between the quality of the signals treated with some of the versions of the technique, and the value of the oversubtraction and spectral floor parameter, used on this versions, was observed in the results. The results show that an increase of the oversubtraction parameter, used to enhance the effect of the technique on the intelligibility of the speech signal, deteriorates the quality of the signals. Intellibility was evaluated using the Articulation Index while the quality was evaluated using the Itakura-Saito Distance and the Log-Likehood-Ratio.","PeriodicalId":359994,"journal":{"name":"Symposium of Signals, Images and Artificial Vision - 2013: STSIVA - 2013","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the parameters of spectral subtraction techniques and its effects on speech signal quality\",\"authors\":\"H. Carvajal, N. García\",\"doi\":\"10.1109/STSIVA.2013.6644918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents the results of tests conducted to evaluate various versions of the spectral subtraction technique. Brief descriptions of the versions of the techniques evaluated and the measures used to evaluate them are given. The tests were conducted using a set of signals, containing voices of male speakers, that were contaminated with white gaussian noise at different levels of contamination. A relation between the quality of the signals treated with some of the versions of the technique, and the value of the oversubtraction and spectral floor parameter, used on this versions, was observed in the results. The results show that an increase of the oversubtraction parameter, used to enhance the effect of the technique on the intelligibility of the speech signal, deteriorates the quality of the signals. Intellibility was evaluated using the Articulation Index while the quality was evaluated using the Itakura-Saito Distance and the Log-Likehood-Ratio.\",\"PeriodicalId\":359994,\"journal\":{\"name\":\"Symposium of Signals, Images and Artificial Vision - 2013: STSIVA - 2013\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Symposium of Signals, Images and Artificial Vision - 2013: STSIVA - 2013\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STSIVA.2013.6644918\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Symposium of Signals, Images and Artificial Vision - 2013: STSIVA - 2013","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STSIVA.2013.6644918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了评估各种版本的谱减法技术的测试结果。简要描述了所评估的技术版本和用于评估它们的措施。测试是用一组信号进行的,其中包括男性说话者的声音,这些信号被不同程度的高斯白噪声污染了。在结果中观察到,用该技术的某些版本处理的信号的质量与在此版本上使用的过减法和谱底参数的值之间存在关系。结果表明,为了提高语音信号的可理解性,增大过减法参数会使语音信号的质量下降。使用发音指数评估不清度,使用Itakura-Saito距离和对数似然比评估质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the parameters of spectral subtraction techniques and its effects on speech signal quality
This article presents the results of tests conducted to evaluate various versions of the spectral subtraction technique. Brief descriptions of the versions of the techniques evaluated and the measures used to evaluate them are given. The tests were conducted using a set of signals, containing voices of male speakers, that were contaminated with white gaussian noise at different levels of contamination. A relation between the quality of the signals treated with some of the versions of the technique, and the value of the oversubtraction and spectral floor parameter, used on this versions, was observed in the results. The results show that an increase of the oversubtraction parameter, used to enhance the effect of the technique on the intelligibility of the speech signal, deteriorates the quality of the signals. Intellibility was evaluated using the Articulation Index while the quality was evaluated using the Itakura-Saito Distance and the Log-Likehood-Ratio.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信