{"title":"将风力涡轮机集成到德国输电系统的先进电网要求","authors":"Istvan Erlich, W. Winter, A. Dittrich","doi":"10.1109/PES.2006.1709340","DOIUrl":null,"url":null,"abstract":"In Germany 18 GW wind power will have been installed by the end of 2005. Until 2020, this figure reaches the 50 GW mark. Based on the results of recent studies and on the experience with existing wind projects modification of the existing grid code for connection and operation of wind farms in the high voltage grid is necessary. The paper discusses main issues of the suggested requirements by highlighting major changes and extensions. The topics considered are fault ride-through, grid voltage maintenance respective voltage control, system monitoring and protection as well as retrofitting of old units. The new requirements are defined taking into account some new developments in wind turbine technologies which should be utilized in the future to meet grid requirement. Monitoring and system protection is defined under the aspect of sustainability of the measures introduced","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"270","resultStr":"{\"title\":\"Advanced grid requirements for the integration of wind turbines into the German transmission system\",\"authors\":\"Istvan Erlich, W. Winter, A. Dittrich\",\"doi\":\"10.1109/PES.2006.1709340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In Germany 18 GW wind power will have been installed by the end of 2005. Until 2020, this figure reaches the 50 GW mark. Based on the results of recent studies and on the experience with existing wind projects modification of the existing grid code for connection and operation of wind farms in the high voltage grid is necessary. The paper discusses main issues of the suggested requirements by highlighting major changes and extensions. The topics considered are fault ride-through, grid voltage maintenance respective voltage control, system monitoring and protection as well as retrofitting of old units. The new requirements are defined taking into account some new developments in wind turbine technologies which should be utilized in the future to meet grid requirement. Monitoring and system protection is defined under the aspect of sustainability of the measures introduced\",\"PeriodicalId\":267582,\"journal\":{\"name\":\"2006 IEEE Power Engineering Society General Meeting\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"270\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2006.1709340\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Advanced grid requirements for the integration of wind turbines into the German transmission system
In Germany 18 GW wind power will have been installed by the end of 2005. Until 2020, this figure reaches the 50 GW mark. Based on the results of recent studies and on the experience with existing wind projects modification of the existing grid code for connection and operation of wind farms in the high voltage grid is necessary. The paper discusses main issues of the suggested requirements by highlighting major changes and extensions. The topics considered are fault ride-through, grid voltage maintenance respective voltage control, system monitoring and protection as well as retrofitting of old units. The new requirements are defined taking into account some new developments in wind turbine technologies which should be utilized in the future to meet grid requirement. Monitoring and system protection is defined under the aspect of sustainability of the measures introduced