采用新型SMR的高频隔离UPS

R. Yamada, K. Kuroki, J. Shinohara, T. Kagotani
{"title":"采用新型SMR的高频隔离UPS","authors":"R. Yamada, K. Kuroki, J. Shinohara, T. Kagotani","doi":"10.1109/IECON.1993.339247","DOIUrl":null,"url":null,"abstract":"This paper concerns a newly developed 2 to 5 kVA, high-frequency isolation type UPS (uninterruptible power system). This UPS features a novel SMR (switch mode rectifier) that is applied to the input converter section and a newly developed low-loss IGBT (insulated gate bipolar transistor) that is employed in both inverter and converter sections. The SMR, as a single converter, has functions for high-frequency isolation, enhancement of input power factor and stabilization of DC output voltage. In the case of a new type of DC-clamped SMR (DCC-SMR), the number of current flowing devices in the frequency changer has been reduced to 1/2 of those compared with systems using a conventional SMR, and simplification of the snubber discharge circuit has also been achieved. Owing to the above, this newly developed UPS not only has small volume and weight, about 1/2 of that of commercial frequency isolation type UPSs, but also provides high efficiency-at least equivalent to that of the latter UPS.<<ETX>>","PeriodicalId":132101,"journal":{"name":"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":"{\"title\":\"High-frequency isolation UPS with novel SMR\",\"authors\":\"R. Yamada, K. Kuroki, J. Shinohara, T. Kagotani\",\"doi\":\"10.1109/IECON.1993.339247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper concerns a newly developed 2 to 5 kVA, high-frequency isolation type UPS (uninterruptible power system). This UPS features a novel SMR (switch mode rectifier) that is applied to the input converter section and a newly developed low-loss IGBT (insulated gate bipolar transistor) that is employed in both inverter and converter sections. The SMR, as a single converter, has functions for high-frequency isolation, enhancement of input power factor and stabilization of DC output voltage. In the case of a new type of DC-clamped SMR (DCC-SMR), the number of current flowing devices in the frequency changer has been reduced to 1/2 of those compared with systems using a conventional SMR, and simplification of the snubber discharge circuit has also been achieved. Owing to the above, this newly developed UPS not only has small volume and weight, about 1/2 of that of commercial frequency isolation type UPSs, but also provides high efficiency-at least equivalent to that of the latter UPS.<<ETX>>\",\"PeriodicalId\":132101,\"journal\":{\"name\":\"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1993.339247\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1993.339247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

摘要

本文介绍了一种新研制的2 ~ 5kva高频隔离式不间断电源系统。该UPS的特点是应用于输入转换器部分的新型SMR(开关模式整流器)和应用于逆变器和转换器部分的新开发的低损耗IGBT(绝缘栅双极晶体管)。SMR作为单一变换器,具有高频隔离、提高输入功率因数和稳定直流输出电压等功能。在新型直流箝位SMR (dc -SMR)中,变频器中的电流流动器件数量减少到传统SMR系统的1/2,并且缓冲放电电路也得到了简化。因此,这款新开发的UPS不仅体积和重量小,约为商用频率隔离型UPS的1/2,而且效率高,至少相当于后者的UPS
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High-frequency isolation UPS with novel SMR
This paper concerns a newly developed 2 to 5 kVA, high-frequency isolation type UPS (uninterruptible power system). This UPS features a novel SMR (switch mode rectifier) that is applied to the input converter section and a newly developed low-loss IGBT (insulated gate bipolar transistor) that is employed in both inverter and converter sections. The SMR, as a single converter, has functions for high-frequency isolation, enhancement of input power factor and stabilization of DC output voltage. In the case of a new type of DC-clamped SMR (DCC-SMR), the number of current flowing devices in the frequency changer has been reduced to 1/2 of those compared with systems using a conventional SMR, and simplification of the snubber discharge circuit has also been achieved. Owing to the above, this newly developed UPS not only has small volume and weight, about 1/2 of that of commercial frequency isolation type UPSs, but also provides high efficiency-at least equivalent to that of the latter UPS.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信