PET扫描仪的基本性能,EXACT HR/sup +/,具有可调的数据采集参数

T. Hasegawa, Y. Wada, H. Murayama, T. Nakajima
{"title":"PET扫描仪的基本性能,EXACT HR/sup +/,具有可调的数据采集参数","authors":"T. Hasegawa, Y. Wada, H. Murayama, T. Nakajima","doi":"10.1109/NSSMIC.1998.773872","DOIUrl":null,"url":null,"abstract":"The performance of ECAT EXACT HR/sup +/ (Siemens/CTI) was analyzed with reference to the following adjustable data-acquisition parameters in the operation software: maximum ring difference, span, angular compression and overlap. The standard protocol by the National Electrical Manufacturers Association (NEMA) was followed with minor modification. Scanner performance such as sensitivity and resolution was shown to be dependent on the parameters in a variety of manners in the three-dimensional mode. The advantages and disadvantages of altering the data-acquisition parameters were discussed. It was concluded that the data-acquisition parameters should be carefully selected for a specific clinical situation in order to maximize the efficiency of PET measurement.","PeriodicalId":129202,"journal":{"name":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Basic performance of the PET scanner, EXACT HR/sup +/, with adjustable data-acquisition parameters\",\"authors\":\"T. Hasegawa, Y. Wada, H. Murayama, T. Nakajima\",\"doi\":\"10.1109/NSSMIC.1998.773872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of ECAT EXACT HR/sup +/ (Siemens/CTI) was analyzed with reference to the following adjustable data-acquisition parameters in the operation software: maximum ring difference, span, angular compression and overlap. The standard protocol by the National Electrical Manufacturers Association (NEMA) was followed with minor modification. Scanner performance such as sensitivity and resolution was shown to be dependent on the parameters in a variety of manners in the three-dimensional mode. The advantages and disadvantages of altering the data-acquisition parameters were discussed. It was concluded that the data-acquisition parameters should be carefully selected for a specific clinical situation in order to maximize the efficiency of PET measurement.\",\"PeriodicalId\":129202,\"journal\":{\"name\":\"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1998.773872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1998.773872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

参考操作软件中可调的数据采集参数:最大环差、跨度、角压缩和重叠,分析ECAT EXACT HR/sup +/ (Siemens/CTI)的性能。根据美国电气制造商协会(NEMA)的标准协议进行了轻微修改。扫描仪的性能,如灵敏度和分辨率显示依赖于各种方式的参数在三维模式。讨论了改变数据采集参数的优缺点。综上所述,为了使PET测量的效率最大化,应根据具体的临床情况仔细选择数据采集参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Basic performance of the PET scanner, EXACT HR/sup +/, with adjustable data-acquisition parameters
The performance of ECAT EXACT HR/sup +/ (Siemens/CTI) was analyzed with reference to the following adjustable data-acquisition parameters in the operation software: maximum ring difference, span, angular compression and overlap. The standard protocol by the National Electrical Manufacturers Association (NEMA) was followed with minor modification. Scanner performance such as sensitivity and resolution was shown to be dependent on the parameters in a variety of manners in the three-dimensional mode. The advantages and disadvantages of altering the data-acquisition parameters were discussed. It was concluded that the data-acquisition parameters should be carefully selected for a specific clinical situation in order to maximize the efficiency of PET measurement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信