X. Cai, Brian J. Roscoe, Z. Alamgir, S. Sani, R. Wang, S. Schuckers, Alexandru Stoian, Charles J. Robinson
{"title":"头部加速度计测量中与心脏相关的地震脉冲的延迟","authors":"X. Cai, Brian J. Roscoe, Z. Alamgir, S. Sani, R. Wang, S. Schuckers, Alexandru Stoian, Charles J. Robinson","doi":"10.1109/NEBEC.2013.107","DOIUrl":null,"url":null,"abstract":"A 60 s time-series record of AP, RL and Z-axes data is taken from a head-mounted 3-axis accelerometer, along with a 3-lead ECG signal. The R-wave peak is then used as a trigger to conduct spike-triggered averaging of the accelerometer data. As a result, a cardiac-linked acceleration waveform appears. The latencies of these resultant waves are compared to the latencies produced when an accelerometer is placed on the chest wall.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Latencies of Cardiac-Linked Seismic Pulses in Head Accelerometer Measurements\",\"authors\":\"X. Cai, Brian J. Roscoe, Z. Alamgir, S. Sani, R. Wang, S. Schuckers, Alexandru Stoian, Charles J. Robinson\",\"doi\":\"10.1109/NEBEC.2013.107\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 60 s time-series record of AP, RL and Z-axes data is taken from a head-mounted 3-axis accelerometer, along with a 3-lead ECG signal. The R-wave peak is then used as a trigger to conduct spike-triggered averaging of the accelerometer data. As a result, a cardiac-linked acceleration waveform appears. The latencies of these resultant waves are compared to the latencies produced when an accelerometer is placed on the chest wall.\",\"PeriodicalId\":153112,\"journal\":{\"name\":\"2013 39th Annual Northeast Bioengineering Conference\",\"volume\":\"82 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 39th Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBEC.2013.107\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Latencies of Cardiac-Linked Seismic Pulses in Head Accelerometer Measurements
A 60 s time-series record of AP, RL and Z-axes data is taken from a head-mounted 3-axis accelerometer, along with a 3-lead ECG signal. The R-wave peak is then used as a trigger to conduct spike-triggered averaging of the accelerometer data. As a result, a cardiac-linked acceleration waveform appears. The latencies of these resultant waves are compared to the latencies produced when an accelerometer is placed on the chest wall.